1990
DOI: 10.1016/s0003-2670(00)83594-1
|View full text |Cite
|
Sign up to set email alerts
|

Determination of nitrate with a flow-injection system combining square-wave polarographic detection with on-line deaeration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

1994
1994
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(2 citation statements)
references
References 14 publications
0
1
0
Order By: Relevance
“…A stronger influence of pH variation on the ES ↔ PN redox transition than on the LS ↔ ES redox transition has also been reported, which also agrees with our system [78,79]. The results indicated that both LS ↔ ES and ES ↔ PN redox transitions of GA@PAni-CNT electrode were more easily observed in the phosphate buffer electrolyte in the pH range The GA@PAni-CNT electrode shows a detection limit (3SD/b) of 0.42 µM at a signal-to-noise ratio of 3, which was quite promising and lower than the values reported so far (Table 1) for indirect electrochemical determination of NO 3 − using modified zeolitic carbon paste electrode and Ag-doped zeolite-expanded graphite-epoxy electrodes [33,36,41,42,88]. The GA@PAni-CNT electrode illustrated a sensitivity of ~443 A/M cm 2 , obtained through the slope of the linear regression.…”
Section: Buffer Electrolyte Selection and Ph Studymentioning
confidence: 67%
“…A stronger influence of pH variation on the ES ↔ PN redox transition than on the LS ↔ ES redox transition has also been reported, which also agrees with our system [78,79]. The results indicated that both LS ↔ ES and ES ↔ PN redox transitions of GA@PAni-CNT electrode were more easily observed in the phosphate buffer electrolyte in the pH range The GA@PAni-CNT electrode shows a detection limit (3SD/b) of 0.42 µM at a signal-to-noise ratio of 3, which was quite promising and lower than the values reported so far (Table 1) for indirect electrochemical determination of NO 3 − using modified zeolitic carbon paste electrode and Ag-doped zeolite-expanded graphite-epoxy electrodes [33,36,41,42,88]. The GA@PAni-CNT electrode illustrated a sensitivity of ~443 A/M cm 2 , obtained through the slope of the linear regression.…”
Section: Buffer Electrolyte Selection and Ph Studymentioning
confidence: 67%
“…The combination of the fl.ow-injection analysis with square-wave voltammetry and on-line deaeration has been applied to the determination of nitrates, utilizing the catalytic reaction between these ions and uranyl ions. This simple method with the detection Iimit of 2 .uM nitrate was applied to the determination of N03 in drinking and river waters [202]. Comparative study of a thin-layer cell for the investigation of stationary and streaming solutions [203] has shown little differences between the fl.owing and quiescent solution in very narrow cells.…”
Section: Selected Applications Of Hydrodynamic E/ectrode Systemsmentioning
confidence: 99%