1989
DOI: 10.1021/ac00180a011
|View full text |Cite
|
Sign up to set email alerts
|

Determination of naphthalene-2,3-dicarboxaldehyde-labeled amino acids by open tubular liquid chromatography with electrochemical detection

Abstract: Naphthalene-2,3-dicarboxaldehyde (NDA) has been investigated as a new derivatizing reagent for the electrochemical detection of tagged amino acids. Gradient elution allowed for the separation of 18 NDA-derivatized amino acids on an open tubular liquid chromatography column in less than 50 min. Gradient elution and electrochemical detection were found to be compatible. A detection limit of 36 amol was obtained for the asparagine-NDA derivative. The usefulness of this technique for quantitation was demonstrated … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
29
0

Year Published

1998
1998
2010
2010

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 74 publications
(30 citation statements)
references
References 25 publications
1
29
0
Order By: Relevance
“…Therefore, fluorescence probes are extensively used in physical, chemical and biological sciences for investigating the structure and dynamics of living system [13,14]. Other techniques used to improve detection limits are micro-column LC [15] and CE [16]. At present, popular methods for the determination of aliphatic amines are pre-column and post-column derivatization with fluorescence detection.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, fluorescence probes are extensively used in physical, chemical and biological sciences for investigating the structure and dynamics of living system [13,14]. Other techniques used to improve detection limits are micro-column LC [15] and CE [16]. At present, popular methods for the determination of aliphatic amines are pre-column and post-column derivatization with fluorescence detection.…”
Section: Introductionmentioning
confidence: 99%
“…Electrochemical detection circumvents the problem of fluorescence quenching from amino acid derivatives. Detection limits in the subfemtomole region have been reported for NDA derivatives with electrochemical detection [16]. These levels are even lower than those reported for laser-induced fluorescence detection [12].…”
Section: Introductionmentioning
confidence: 78%
“…31 NDA has been used as catecholamines ͑e.g., dopamine, norepinephrine͒, labeled reagent in single cell analysis by capillary electrophoresis. 32 In this study we used NDA to stain SH-SY5Y neuroblastoma cells.…”
Section: A Fluorescence Imaging Evaluationmentioning
confidence: 99%