Determination of Methoxyl and Ethoxyl Groups in Acetals and Easily Volatile Alcohols

Abstract: D e p a r t m e n t of C h e m i s t r y , T h e O h i o S t a t e University, C o l u m b u s 10, O h i oA n apparatus and procedure for the quantitative semimicro-and microdetermination of methoxyl and ethoxyl groups i n acetals and easily volatile alcohols are described. A modified reaction flask, scrubber, and receiver are incorporated in the all-glass apparatus. Both solid and liquid samples are introduced below the surface of the reaction mixture by means of sealed containers. HE usual procedures for the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0

Year Published

1953
1953
1997
1997

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…302 ' 303 For rapid identification of methyl ether, methylamino, and methylthio groups, and for quantitative determination of such derivatives, n.m.r. 302 ' 303 For rapid identification of methyl ether, methylamino, and methylthio groups, and for quantitative determination of such derivatives, n.m.r.…”
Section: Determination Of Ethersmentioning
confidence: 99%
“…302 ' 303 For rapid identification of methyl ether, methylamino, and methylthio groups, and for quantitative determination of such derivatives, n.m.r. 302 ' 303 For rapid identification of methyl ether, methylamino, and methylthio groups, and for quantitative determination of such derivatives, n.m.r.…”
Section: Determination Of Ethersmentioning
confidence: 99%
“…and finally dried to constant weight in a vacuum desiccator. This product was then analyzed for methoxyl (9), and the values reported (Table 11) represent the mean of two determinations which differed from each other by less than one per cent of the Iclason lignin. The alkaline nitrobenzene oxidations were made on small samples (ca.…”
Section: General Reaction Procedzlrementioning
confidence: 99%
“…Methoxyl analyses were carried out by the method of Hoffman and Wolfrom (13). A Glas-Col heating mantle for the reaction flask was found to give less bumping and better all-round performance than did an ordinary flame.…”
Section: Accessibility To Thallous Etlzylatementioning