2012
DOI: 10.1007/s00604-012-0879-1
|View full text |Cite
|
Sign up to set email alerts
|

Determination of methamphetamine, amphetamine and ecstasy by inside-needle adsorption trap based on molecularly imprinted polymer followed by GC-FID determination

Abstract: We have developed a solvent-free and sensitive method for the identification and quantification of methamphetamine (MAMP), amphetamine (AMP) and ecstasy (MDMA) in human urine. It is based on the use of an inside-needle adsorption trap (INAT) and a molecularly imprinted polymer (MIP). The MAMP-MIP layer was coated on the internal surface of a hollow stainless steel needle, which was oxidized and silylated. It was used as the extraction needle. A model solution containing the drugs was slowly passed through the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(20 citation statements)
references
References 27 publications
0
18
0
Order By: Relevance
“…However, poor selectivity and limited applicability to samples with complex matrices remain problematic [24]. Functionalized or polymerfunctionalized carbon nanomaterials [125,126,127] Ionic liquid-mediated SPME coating [128,129] Sol-gel derived polymeric ionic liquid-based SPME coatings [130,131] Sol-gel ordered mesoporous silica SPME coating [132,133] Sol-gel coating on metal wires [134,135] Sol-gel molecularly imprinted polymer coatings [113,136] Aptamer Sol-gel SPME [137] Nanomaterials [138,139] Immunoaffinity SPME [140] Molecularly imprinted polymers [141,142] Substrate-bonded ionic liquid coatings [143] Substrate-bonded polymeric ionic liquid coatings [144] Electrodeposition Electropolymerized conductive polymers [88,[145][146][147] Electropolymerized conductive polymers nanocomposite [148,149] Conductive polymer-ionic liquid composites [150,151] Metal oxides [152,153] Anodized metal wires Metal oxides […”
Section: Fiber Coatingsmentioning
confidence: 99%
“…However, poor selectivity and limited applicability to samples with complex matrices remain problematic [24]. Functionalized or polymerfunctionalized carbon nanomaterials [125,126,127] Ionic liquid-mediated SPME coating [128,129] Sol-gel derived polymeric ionic liquid-based SPME coatings [130,131] Sol-gel ordered mesoporous silica SPME coating [132,133] Sol-gel coating on metal wires [134,135] Sol-gel molecularly imprinted polymer coatings [113,136] Aptamer Sol-gel SPME [137] Nanomaterials [138,139] Immunoaffinity SPME [140] Molecularly imprinted polymers [141,142] Substrate-bonded ionic liquid coatings [143] Substrate-bonded polymeric ionic liquid coatings [144] Electrodeposition Electropolymerized conductive polymers [88,[145][146][147] Electropolymerized conductive polymers nanocomposite [148,149] Conductive polymer-ionic liquid composites [150,151] Metal oxides [152,153] Anodized metal wires Metal oxides […”
Section: Fiber Coatingsmentioning
confidence: 99%
“…The column, injector and detector temperature were set at 140°C to 270°C, 250°C, 300°C, respectively and detection was using NPD [179]. Other GC methods for the quantification of AMP and MPH in human biological samples [180][181][182][183][184][185][186][187][188] are reported in Table 3.…”
Section: Gas Chromatography (Gc)mentioning
confidence: 99%
“…For synthesis of the MIPs towards N-FA (N-formylamphetamine, an intermediate in the production of amphetamine by the Leukart reaction) three approaches, based on the use of different monomers, cross linkers and polymerization techniques were compared (Table 1). The first technique was based on the modified procedure described by Djozan (Djozan et al 2012) (MIPs1) and implemented MAA as functional monomer and EGDMA as cross-linker. First, 50 μmol of N-FA were dissolved in 100μL of methanol, then subsequently diluted in 10 mL of ACN.…”
Section: Synthesis Of N-fa-imprinted Polymersmentioning
confidence: 99%
“…When scanning was completed, as one of the most commonly used monomers. It was reported as appropriate for MIPs toward amphetamine, which is a structural analog of N-FA (Djozan et al 2012). After investigation of monomertemplate interactions the decision to change functional monomer was taken.…”
Section: Immobilization Of Polymer Beads On the Gold Electrodementioning
confidence: 99%