2006
DOI: 10.1016/j.sab.2006.10.004
|View full text |Cite
|
Sign up to set email alerts
|

Determination of mercury in organic solvents and gas condensates by μflow-injection — inductively coupled plasma mass spectrometry using a modified total consumption micronebulizer fitted with single pass spray chamber

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
29
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(30 citation statements)
references
References 24 publications
1
29
0
Order By: Relevance
“…ICP-MS measurements were carried out using an Element XSeries II (ThermoFisher Scientic, USA, and the operating conditions used are given in Table 1) and 202 Hg (maximal abundance and without isobaric elements interferences) was selected as the investigating isotope. 5 A Mars Xpress (CEM, USA) microwave oven equipped with a rotor for forty PTFE vessels was used for digestion of gas condensate, and the heating program was performed as described in the literature. 13 A Himac CR22G (Hitachi, Japan) high speed refrigerated centrifuge was also used in the experiments.…”
Section: Apparatusmentioning
confidence: 99%
See 2 more Smart Citations
“…ICP-MS measurements were carried out using an Element XSeries II (ThermoFisher Scientic, USA, and the operating conditions used are given in Table 1) and 202 Hg (maximal abundance and without isobaric elements interferences) was selected as the investigating isotope. 5 A Mars Xpress (CEM, USA) microwave oven equipped with a rotor for forty PTFE vessels was used for digestion of gas condensate, and the heating program was performed as described in the literature. 13 A Himac CR22G (Hitachi, Japan) high speed refrigerated centrifuge was also used in the experiments.…”
Section: Apparatusmentioning
confidence: 99%
“…At present, there are few research reports on methods for the determination of Hg in gas condensates. [5][6][7] However, there are multiple reports on methods for the determination of Hg in oils of a similar nature to gas condensates, and various sample pretreatment methods and determination techniques can be used. [8][9][10][11][12] Sample decomposition methods include thermal decomposition techniques 8 and wet-chemistry procedures.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…12 The IFP Energies Nouvelles and the University of Pau have also wrote many papers on crude oil analysis using ICPMS. [12][13][14][15][16][17][18][19][20][21] For these types of samples, the transfer line between the GC and ICPMS is extremely important, and can be the limiting factor. In this work, the transfer line used to couple the GC column to the ICPMS must be able to quantitatively convey compounds whose boiling points can exceed 540 C (>1000 F) into the ICP plasma.…”
Section: Introductionmentioning
confidence: 99%
“…Single-pass or cylindrical-type spray chambers, designed for low-flow introduction, 45,46 provide high efficiency and reduced memory effects; 46 however, these designs are unsuitable for conventional ICP analysis and are typically used when electrophoretic or chromatographic separations are employed in conjunction with ICP detection. 47,48 Spray chambers have also been blamed for the retention of elements such as B and Hg.…”
Section: Introductionmentioning