2020
DOI: 10.1016/j.talanta.2020.120907
|View full text |Cite
|
Sign up to set email alerts
|

Determination of lithium in dried blood spots and dried plasma spots by graphite furnace atomic absorption spectrometry: Method development, validation and clinical application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
15
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(15 citation statements)
references
References 17 publications
0
15
0
Order By: Relevance
“…The DBS sampling has some advantages in comparison with the standard venous blood collecting, which include its small collection volume, having painless and easy sample collection with minimal training required, and being stable and transportable at ambient temperatures [ 20 ]. Dried plasma spots (DPS), representative of serum levels, can also be obtained from a finger prick with the use of membranes that filter erythrocytes [ 21 ]. Determination of lithium in dried blood spots (DBS) and dried plasma spots (DPS) by graphite furnace atomic absorption spectrometry (GFAAS) has been investigated [ 21 ].…”
Section: Therapeutic Monitoring Of Lithium Levels In Different Biolog...mentioning
confidence: 99%
“…The DBS sampling has some advantages in comparison with the standard venous blood collecting, which include its small collection volume, having painless and easy sample collection with minimal training required, and being stable and transportable at ambient temperatures [ 20 ]. Dried plasma spots (DPS), representative of serum levels, can also be obtained from a finger prick with the use of membranes that filter erythrocytes [ 21 ]. Determination of lithium in dried blood spots (DBS) and dried plasma spots (DPS) by graphite furnace atomic absorption spectrometry (GFAAS) has been investigated [ 21 ].…”
Section: Therapeutic Monitoring Of Lithium Levels In Different Biolog...mentioning
confidence: 99%
“… LC-HRMS [ 114 ] VAMS Blood Hydroxychloroquine 10 LC-MS/MS [ 115 ] DBS Blood Hydroxychloroquine n.s. LC-MS/MS [ 116 ] DBS Blood Li + 50 GF-AAS [ 118 ] DPS Plasma Li + 20 GF-AAS [ 118 ] DBS Blood Cyclosporin A n.s. LC-MS/MS [ 120 ] Abbreviations : AAS, Atomic Absorption Spectrometry; BD, Blood Drop (not dried); BFS, BioFluid Sampler; BMS, Bronchoscopic MicroSample; DBS, Dried Blood Spots; DMKS, Dried MilK Spots; DPS, Dried Plasma Spots; DOFS, Dried Oral Fluid Spots; DUS, Dried Urine Spots; EBC, Exhaled Breath Condensate; ELF, Epithelial Lining Fluid; FL, FLuorescence detection; FPSE, Fabric-Phase Sorptive Extraction; GF, Graphite Furnace; HRMS, High-Resolution Mass Spectrometry; LC, Liquid Chromatography or high-performance Liquid Chromatography; MS/MS, tandem Mass Spectrometry; NB, Northern Blotting; n.s., not specified (for BD and DBS it usually ranges from 50 to 200 μL); NSAID, Non-Steroidal Anti-Inflammatory Drug; PCR, Polymerase Chain Reaction; PS, Paper Spray; SB, Southern Blotting; SPE, Solid-Phase Extraction; SPME, Solid-Phase MicroExtraction; UHPLC, Ultra-High-Performance Liquid Chromatography; VAMS, Volumetric Absorptive MicroSampling.…”
Section: Microsampling and Sars-cov-2mentioning
confidence: 99%
“…Lithium salts, usually administered to treat bipolar disorder, have also demonstrated some antiviral activity in preclinical studies [ 117 ]. Lithium requires constant TDM during the therapy, so it is a prime candidate for microsampling application; however, until now just DBS and DPS have been used for this purpose [ 118 ].…”
Section: Microsampling and Sars-cov-2mentioning
confidence: 99%
“…Several analytical methods for the quantification of Li in biological samples have been proposed, including atomic absorption spectrophotometry (AAS) [3], inductively coupled plasma (ICP) optical emission spectroscopy (OES) [4], and ICP mass spectrometry (MS) [5]. The development of ICP-based instrumentation has facilitated the simultaneous quantification of several elements of medical interest with sufficient accuracy (trueness and precision) [6][7][8].…”
Section: Introductionmentioning
confidence: 99%