1987
DOI: 10.1016/0002-9149(87)91191-x
|View full text |Cite
|
Sign up to set email alerts
|

Determination of left ventricular ejection fraction by computer densitometric analysis of digital subtraction angiography: Experimental validation and correlation with area-length methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

1991
1991
1996
1996

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…This comparison demonstrated that the dual-energy images were of sufficient quality to support quantitative analysis techniques. Two important quantitative techniques are densitometric analysis [7][8][9] and parametric imaging [17]. Both of these methodologies require some means of subtracting image structures unrelated to the signal of interest.…”
Section: Misregistration Artifactsmentioning
confidence: 99%
See 1 more Smart Citation
“…This comparison demonstrated that the dual-energy images were of sufficient quality to support quantitative analysis techniques. Two important quantitative techniques are densitometric analysis [7][8][9] and parametric imaging [17]. Both of these methodologies require some means of subtracting image structures unrelated to the signal of interest.…”
Section: Misregistration Artifactsmentioning
confidence: 99%
“…Contrast enhancement allows ventriculography to be performed with direct left ventricular injection of small amounts of contrast material [1][2][3] or with a venous injection [3][4][5][6]. Subtraction allows the determination of ejection fractions from high resolution images using an intravenous injection and videodensitometric techniques [7][8][9]. The potential for measuring absolute left ventricular volume exists [10].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, formerly videodensitometry was tested experimentally by electromagnetic flowmeters [1,2,11] and clinically by comparing the results derived from videometry and thermodilution [8,12,13]. In this study for the first time the method was validated by generating and evaluating well defined 'in vitro angiocardiograms' (Fig.…”
Section: Discussionmentioning
confidence: 99%
“…For analog videodensitometry, to remove these pre-contrast fluctuations, So and Do are measured in the time-density curve before contrast injection [1,7,8]. For digital densitometry they can be removed by ECG gated mask image subtraction [14].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation