1989
DOI: 10.1042/bj2590545
|View full text |Cite
|
Sign up to set email alerts
|

Determination of intracellular nitrate

Abstract: A sensitive procedure has been developed for the determination of intracellular nitrate. The method includes: (i) preparation of cell lysates in 2 M-H3PO4 after separation of cells from the outer medium by rapid centrifugation through a layer of silicone oil, and (ii) subsequent nitrate analysis by ion-exchange h.p.l.c. with, as mobile phase, a solution containing 50 mM-H3PO4 and 2% (v/v) tetrahydrofuran, adjusted to pH 1.9 with NaOH. The determination of nitrate is subjected to interference by chloride and su… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
20
0

Year Published

1990
1990
2010
2010

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(21 citation statements)
references
References 18 publications
(24 reference statements)
1
20
0
Order By: Relevance
“…Elemental analysis of washed and dried samples was performed with a Carlo Erba Strumentazione model 1106/R analyzer. Nitrate concentration in the medium was determined in the supernatant resulting from centrifugation of the cell suspension (3,000g, 5 min), using HPLC-chromatography as described by Romero et al (1989).…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…Elemental analysis of washed and dried samples was performed with a Carlo Erba Strumentazione model 1106/R analyzer. Nitrate concentration in the medium was determined in the supernatant resulting from centrifugation of the cell suspension (3,000g, 5 min), using HPLC-chromatography as described by Romero et al (1989).…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…Ion-exchange high-performance liquid chromatography was used to analyze nitrite/nitrate (NOx) levels as initially described by Romero et al 20 cGMP levels were measured in the LAD by standard radioimmunoassay as previously described. 18 (2), the first diagonal branch of the LAD artery (3), and the great cardiac vein (6).…”
Section: Measurement Of Nitrite/nitrate and Cgmpmentioning
confidence: 99%
“…Nitrate was detected at 210 nm using a Waters 2996 photodiode‐array detector (Waters, Mildford, MA, USA). For nitrate quantification of the samples, a calibration curve with known nitrate concentrations was previously performed (Romero et al. 1989).…”
mentioning