2011
DOI: 10.1002/jssc.201100673
|View full text |Cite
|
Sign up to set email alerts
|

Determination of hydrate inhibitor in crude oil by nanoextraction–gas chromatography

Abstract: This work focused on the quantitation of methanol as a hydrate inhibitor in crude oil. The novelty is nanoextraction of a polar compound from a complex non-polar matrix and selection of the proper fiber with maximum selectivity, loading percent, and lifetime. This approach not only does not require specific instrumentation, such as multiple columns and selective detectors, but also has eliminated the use of organic solvent and avoids the insertion of water inside the GC columns. The objective is optimization o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
0
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 34 publications
(30 reference statements)
0
0
0
Order By: Relevance
“…The ability to use low-field NMR to determine MEG concentrations within 1 wt% accuracy over a range of concentrations improves upon the errors associated with the current onsite monitoring techniques of FTIR (5%) (Shoukat et al, 2019), and Velocity and Conductivity (2-3 wt%) sensors (Sandengen and Kaasa, 2006) (note these studies were performed under comparable ambient temperature conditions to the experiments presented here). Whilst its accuracy has been demonstrated to be comparable to that of Gas Chromatography (1 wt%) (Mokhtari and Pourabdollah, 2012) in the presence of an array of impurities, benchtop NMR spectrometers have the advantage of being easily transportable which facilitates on-site monitoring of samples. The improvement in concentration measurement accuracy may translate to an improvement of MEG re-injections by the same factor.…”
Section: Industrial Relevance Of Resultsmentioning
confidence: 99%
“…The ability to use low-field NMR to determine MEG concentrations within 1 wt% accuracy over a range of concentrations improves upon the errors associated with the current onsite monitoring techniques of FTIR (5%) (Shoukat et al, 2019), and Velocity and Conductivity (2-3 wt%) sensors (Sandengen and Kaasa, 2006) (note these studies were performed under comparable ambient temperature conditions to the experiments presented here). Whilst its accuracy has been demonstrated to be comparable to that of Gas Chromatography (1 wt%) (Mokhtari and Pourabdollah, 2012) in the presence of an array of impurities, benchtop NMR spectrometers have the advantage of being easily transportable which facilitates on-site monitoring of samples. The improvement in concentration measurement accuracy may translate to an improvement of MEG re-injections by the same factor.…”
Section: Industrial Relevance Of Resultsmentioning
confidence: 99%