2018
DOI: 10.1016/j.chroma.2017.11.061
|View full text |Cite
|
Sign up to set email alerts
|

Determination of heavy polycyclic aromatic hydrocarbons by non-aqueous reversed phase liquid chromatography: Application and limitation in refining streams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
26
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(26 citation statements)
references
References 23 publications
0
26
0
Order By: Relevance
“…The same strategy, yet with slight modifications in reaction conditions, led to the mononaphtho‐ and monoanthracenocoronenes C3 and C4 , the derivatives expanding coronene by a naphthalene or an anthracene unit respectively [41] . After these reports, these three hydrocarbons were further used in some applicatioins [42–43] …”
Section: Resultsmentioning
confidence: 99%
“…The same strategy, yet with slight modifications in reaction conditions, led to the mononaphtho‐ and monoanthracenocoronenes C3 and C4 , the derivatives expanding coronene by a naphthalene or an anthracene unit respectively [41] . After these reports, these three hydrocarbons were further used in some applicatioins [42–43] …”
Section: Resultsmentioning
confidence: 99%
“…Indeed, carbon dioxide, which constitutes the SFC mobile phase, can be assimilated to heptane in terms of eluent strength and thus can elute the most apolar compounds. Moreover, no sample preparation is needed, as opposed to LC …”
Section: Resultsmentioning
confidence: 99%
“…Moreover, no sample preparation is needed, as opposed to LC. 16 On the basis of a previous study, methanol was selected as cosolvent. 26 Indeed, Zhang et al showed that on a BEH 2-EP column, among the cosolvents investigated (acetonitrile, methanol, isopropyl alcohol, and hexane), only methanol was able to elute the 16 PAHs, especially the benzo[ghi]perylene, the heaviest PAH studied.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, ionisation competition cannot be solved with IMS-MS. Using chromatographic separation is a relevant way to overcome this limitation; for instance, Panda et al proposed a nonaqueous reversed phase chromatography (NARP) method to quantify PAHs in a recycle UCO stream [25]. Unfortunately this method is well-adapted to streams with low sulphur contents but is not applicable to VGO feedstocks.…”
Section: Introductionmentioning
confidence: 99%