2016
DOI: 10.1016/j.forsciint.2015.12.049
|View full text |Cite
|
Sign up to set email alerts
|

Determination of glyphosate and its metabolite in emergency room in Korea

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(15 citation statements)
references
References 30 publications
0
15
0
Order By: Relevance
“…Finally, Benachour and Séralini (2009) proved that AMPA causes umbilical membrane cell damages and occasionally embryonic or neonatal cells death. No occurrence study has been conducted on blood outside of acute poisoning cases, in which AMPA can reach 2.6 µg/mL of blood (Han et al, 2016). Surprisingly, Li et al (2013) showed that AMPA and glyphosate inhibit growth of cancer cells, but not of healthy cells.…”
Section: Ampa Public Health Concernsmentioning
confidence: 99%
“…Finally, Benachour and Séralini (2009) proved that AMPA causes umbilical membrane cell damages and occasionally embryonic or neonatal cells death. No occurrence study has been conducted on blood outside of acute poisoning cases, in which AMPA can reach 2.6 µg/mL of blood (Han et al, 2016). Surprisingly, Li et al (2013) showed that AMPA and glyphosate inhibit growth of cancer cells, but not of healthy cells.…”
Section: Ampa Public Health Concernsmentioning
confidence: 99%
“…Furthermore, glyphosate was extracted from food samples using various solvents including water (pH 6.5), MeOH and acetonitrile. 10,46 Therefore, in order to know the best solvent for the extraction of glyphosate from food samples, initially we studied the extraction efficiency of glyphosate using water and polar organic solvents (MeOH and EtOH) and its recovery was determined by afore said procedure. To this, the collected potato sample was fortied with 500, 750 and 1000 nM of glyphosate for 24 h at room temperature.…”
Section: Practical Applicationmentioning
confidence: 99%
“…In another study conducted in Korea, glyphosate was detected at range of 1×10 3 -171.1×10 3 µg/L in the blood of female patients (one in human milk) admitted to the emergency room at a university hospital in Korea after glyphosate was self-administered in suicide attempts or by accident. The study illustrated a correlation between the concentration of glyphosate and the clinical symptoms [17]. There was one study in milk samples of lactating women that could not detect either glyphosate or AMPA (LOD and LOQ of 1 and 10 µg/L) [11] as shown in Table 3.…”
Section: Country Reference Concentrationmentioning
confidence: 92%
“…AMPA can be detected in urine at a lower concentration limit of 0.03 µg/L by LC-MS method [10] and 0.15 µg/L by GC-MS/MS [14]. In blood samples, glyphosate can be detected at a minimum of 50 µg/L (LOD) by LC-MS/MS [17] or 10 µg/L by GC-MS [16]. Techniques used to analyze internal exposure measurement as biomarkers were rather more varied than techniques that analyzed glyphosate in ambient air.…”
Section: Analytical Techniques Of Glyphosate Detection From Human Expmentioning
confidence: 99%