2010
DOI: 10.1016/j.radmeas.2010.02.006
|View full text |Cite
|
Sign up to set email alerts
|

Determination of gamma dose and thermal neutron fluence in BNCT beams from the TLD-700 glow curve shape

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
2

Year Published

2014
2014
2020
2020

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 6 publications
0
13
0
2
Order By: Relevance
“…Since the photon sensitivity of 6 Li and 7 Li-enriched TLDs are equivalent, and assuming that their isotopic composition is accurately known, differential measurements with these two types of TLDs could allow estimating both the neutron and photon doses in a mixed field. Researchers from INFN 2 recently proposed a method for determining the photon dose and the thermal neutron fluence in a BNCT n-g field from the glow curves (GCs) of LiF TLDs [11]. This method, illustrated in Figure 3, relies on the deconvolution of the signal of a TLD-700 ( 7 Li-enriched, low neutron sensitivity) irradiated in mixed field, using the GCs obtained from the same TLD irradiated in a pure g field (photon calibration), and with thermal neutrons (neutron calibration).…”
Section: Figmentioning
confidence: 99%
See 4 more Smart Citations
“…Since the photon sensitivity of 6 Li and 7 Li-enriched TLDs are equivalent, and assuming that their isotopic composition is accurately known, differential measurements with these two types of TLDs could allow estimating both the neutron and photon doses in a mixed field. Researchers from INFN 2 recently proposed a method for determining the photon dose and the thermal neutron fluence in a BNCT n-g field from the glow curves (GCs) of LiF TLDs [11]. This method, illustrated in Figure 3, relies on the deconvolution of the signal of a TLD-700 ( 7 Li-enriched, low neutron sensitivity) irradiated in mixed field, using the GCs obtained from the same TLD irradiated in a pure g field (photon calibration), and with thermal neutrons (neutron calibration).…”
Section: Figmentioning
confidence: 99%
“…As shown in Figure 3, the neutron component of the TLD-700 response (pink triangles) and the TLD-600 GC (green squares) are in rather good agreement. Li ∼ 0.01%) irradiated in mixed n-g field (blue line), compared with the glow curve of a TLD-600 ( 6 Li/ 7 Li ∼ 95.6%) irradiated with thermal neutrons (green squares, secondary axis) [11].…”
Section: Figmentioning
confidence: 99%
See 3 more Smart Citations