“…However, studies using the different purification methods reported inconsistent δ 71 Ga values for certain reference materials (Feng et al., 2019; Kato et al., 2017, Wimpenny et al., 2020; Yuan et al., 2016; Zhang et al., 2016), requiring further study of technique reliability. We performed an international calibration and comparison of δ 71 Ga values for set reference materials, with results indicating that δ 71 Ga values, relative to both the NIST SRM 994 and IPGP‐Ga standard (Feng et al., 2019; Kato et al., 2017, Yuan et al., 2016; Zhang et al., 2016), of our newly purchased reference materials JG‐2, BHVO‐2, and BCR‐2 were consistent with those reported previously by other laboratories (Figures 11 and 12, Table S9). Inter‐laboratory and international calibration of standards should thus be undertaken regularly to test method reliability and to evaluate possible standard heterogeneity or contamination (Feng et al., 2019; Kato et al., 2017; Wimpenny et al., 2020; Yuan et al., 2016; Zhang et al., 2016).…”