Determination of Electrochemical Electron‐Transfer Reaction Standard Rate Constants at Nanoelectrodes: Standard Rate Constants for Ferrocenylmethyltrimethylammonium(III)/(II) and Hexacyanoferrate(III)/(II)

Abstract: The most common approximation of electroneutrality is inappropriate for analyzing the voltammetric response of nanoelectrodes. Therefore, the microelectrode theory for extracting the standard rate constant k 0 for electron transfer from steady-state voltammograms is invalid for nanoelectrodes. Unlike previous approaches, we considered the influence of the interfacial potential distribution caused by the absence of electroneutrality. We estimated the magnitude of the error at low overpotential incurred as a res… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
13
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 19 publications
1
13
0
Order By: Relevance
“…Potassium ferricyanide, K 3 [Fe(CN) 6 ], was chosen as a model oxidizer because of its stability in water solution (in contrast to unclustered iron salts) and monoelectron oxidative transition Fe 3+ /Fe 2+ (Katafias et al 2008;Zhang et al 2008). Detoxification coefficients D IT and D OxT were calculated to characterize changes in integral toxicity (IT) and oxidative toxicity (OxT) under the action of HS (Tarasova et al 2011).…”
Section: Detoxification Of Oxidizer Solutionsmentioning
confidence: 99%
“…Potassium ferricyanide, K 3 [Fe(CN) 6 ], was chosen as a model oxidizer because of its stability in water solution (in contrast to unclustered iron salts) and monoelectron oxidative transition Fe 3+ /Fe 2+ (Katafias et al 2008;Zhang et al 2008). Detoxification coefficients D IT and D OxT were calculated to characterize changes in integral toxicity (IT) and oxidative toxicity (OxT) under the action of HS (Tarasova et al 2011).…”
Section: Detoxification Of Oxidizer Solutionsmentioning
confidence: 99%
“…The value DI was chosen to evaluate the general toxicity, and T 0. 5 [27,28]. We studied the detailed chemical processes taking place in the enzyme system sensitive to oxidizers.…”
Section: Introductionmentioning
confidence: 99%
“…Historically, experiments undertaken to determine k 0 using macro and ultra-microelectrodes have been diffusion limited as such that low values have been reported. [8][9][10][11] The advent of nanoscale electrodes have eliminated diffusion effects and permitted higher (truer) values to be experimentally determined. 22 Kinetic analysis is undertaken on steady-state CVs of a single electron oxidation of FcCOOH at arrays of three nanowires separated by 5 and 15 mm.…”
Section: Resultsmentioning
confidence: 99%
“…6,7 Consequently, 1-D nanostructures have been employed to explore heterogeneous electron transfer rate constants with rates up to two orders of magnitude higher than previously measured, which are being reported. [8][9][10][11] In addition, electrochemical devices employing discrete nanowire sensors demonstrating highly sensitive detection of key biomolecules including dopamine, 7 hydrogen peroxide 12 and glucose 13 amongst others have recently been reported. Electrodes based on nanowire arrays offer the potential for further enhancements in electroanalysis including: increased signal to noise ratio and increased sensitivity while also allowing quantitative detection at much lower concentrations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation