“…Therefore, using immobilized AAG column for quantitation of drug protein binding still remains questionable. (2) Compound structure diversity, which leads to binding mechanism complexity [24,26]. De Jong and coworkers [24] have shown that a better correlation was obtained with a series of structurally analogous piperazines compared to the structurally heterogeneous compounds.…”
Section: Resultsmentioning
confidence: 99%
“…(2) Compound structure diversity, which leads to binding mechanism complexity [24,26]. De Jong and coworkers [24] have shown that a better correlation was obtained with a series of structurally analogous piperazines compared to the structurally heterogeneous compounds. In order to elute compounds F and G, the mobile phase was modified with higher organic composition [30].…”
Section: Resultsmentioning
confidence: 99%
“…[21][22][23][24][25][26]32,34,5,18]. In this method, a small volume of solution containing the drug of interest is injected to immobilized HSA column, and the capacity factor (k ) is used to evaluate the protein binding strength of the drug.…”
Section: Introductionmentioning
confidence: 99%
“…It has been claimed by many research groups [1,21,24] that the extent of drug protein binding correlates better with the expression of k /(k + 1) than k . Therefore, drug-protein binding percent (%binding) obtained by conventional method is then regressed against k /(k +1), generating a quantitative working curve [21].…”
“…Therefore, using immobilized AAG column for quantitation of drug protein binding still remains questionable. (2) Compound structure diversity, which leads to binding mechanism complexity [24,26]. De Jong and coworkers [24] have shown that a better correlation was obtained with a series of structurally analogous piperazines compared to the structurally heterogeneous compounds.…”
Section: Resultsmentioning
confidence: 99%
“…(2) Compound structure diversity, which leads to binding mechanism complexity [24,26]. De Jong and coworkers [24] have shown that a better correlation was obtained with a series of structurally analogous piperazines compared to the structurally heterogeneous compounds. In order to elute compounds F and G, the mobile phase was modified with higher organic composition [30].…”
Section: Resultsmentioning
confidence: 99%
“…[21][22][23][24][25][26]32,34,5,18]. In this method, a small volume of solution containing the drug of interest is injected to immobilized HSA column, and the capacity factor (k ) is used to evaluate the protein binding strength of the drug.…”
Section: Introductionmentioning
confidence: 99%
“…It has been claimed by many research groups [1,21,24] that the extent of drug protein binding correlates better with the expression of k /(k + 1) than k . Therefore, drug-protein binding percent (%binding) obtained by conventional method is then regressed against k /(k +1), generating a quantitative working curve [21].…”
“…For heterogeneous groups of compounds, in the past low correlation coefficients have been calculated. This demonstrates that the initial method applies only for structurally related compounds (Lammers et al, 1989).…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.