2016
DOI: 10.1002/jssc.201501178
|View full text |Cite
|
Sign up to set email alerts
|

Determination of donepezil in serum samples using molecularly imprinted polymer nanoparticles followed by high‐performance liquid chromatography with ultraviolet detection

Abstract: A molecularly imprinted polymer designed for the selective extraction of donepezil from serum samples was synthesized using a noncovalent molecular imprinting approach. The molecularly imprinted polymer was evaluated chromatographically and then its affinity for donepezil was confirmed by solid-phase extraction. The optimal conditions for solid-phase extraction were provided by cartridge conditioning using acidified water purified from a Milli-Q system, sample loading under basic aqueous conditions, clean-up u… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…The limit of quantification (LOQ) of assay (signal/noise ratio of 20) was 10 ng.mL -1 which was much lower than the minimum therapeutic concentration of MPH in patient serum. LOD and LOQ values obtained in other studies (with similar MISPE method and HPLC assay carried out for other templates) ranged from ng mL -1 to μg mL -1 [14,21]. Also, LOD and LOQ values of HPLC assay of MPH in human serum, determined by other researchers, were less than 1 ng mL -1 and 50 ng mL -1 , respectively [4].…”
Section: Extraction Of Mph From Serum Samplesmentioning
confidence: 59%
See 2 more Smart Citations
“…The limit of quantification (LOQ) of assay (signal/noise ratio of 20) was 10 ng.mL -1 which was much lower than the minimum therapeutic concentration of MPH in patient serum. LOD and LOQ values obtained in other studies (with similar MISPE method and HPLC assay carried out for other templates) ranged from ng mL -1 to μg mL -1 [14,21]. Also, LOD and LOQ values of HPLC assay of MPH in human serum, determined by other researchers, were less than 1 ng mL -1 and 50 ng mL -1 , respectively [4].…”
Section: Extraction Of Mph From Serum Samplesmentioning
confidence: 59%
“…Less polar solvents such as chloroform or hexane increase complex formation, facilitating polar non-covalent interactions such as hydrogen bonding. On the other hand, more polar solvents tend to dissociate the non-covalent interactions in the pre-polymer complex, especially protic solvents which leads to a high degree of disruption to hydrogen bonds [20][21][22]. In this work, two organic solvents (hexane and acetic acid) were tested as the polymerization solvents for optimization of molecular imprinting procedure (Figure 2).…”
Section: Choice Of Functional Monomer and Solventmentioning
confidence: 99%
See 1 more Smart Citation
“…Current methods of miRNA detection are mainly based on PCR , microarray , Northern blotting , and solid‐phase hybridization techniques . However, detection of miRNAs with high sensitivity still remains a great challenge .…”
Section: Introductionmentioning
confidence: 99%
“…However, the adsorption capacity of the polymers is low and their application is not convenient . Due to low recovery rate and efficiency of ordinary MIP, magnetic molecularly imprinted polymer (MMIP) has received considerable attention and extensive application . The advantage of MMIP is separating from extraction system easily by the applied magnetic field .…”
Section: Introductionmentioning
confidence: 99%