1997
DOI: 10.1094/cchem.1997.74.6.745
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Damaged Starch and Diastatic Activity in Wheat Flour Using a Flow‐Injection Analysis Biosensor Method

Abstract: Cereal Chem. 74(6):745-749The determination of damaged starch and diastatic activity in flour was studied using a flow-injection analysis (FIA) biosensor system. The system consisted of an oxygen electrode and an immobilized enzyme column containing purified glucoamylase and glucose oxidase immobilized on activated aminopropyl glass beads. The biosensor system has an optimum pH between 6.5 and 7.5 and an optimum temperature of 35°C for glucose measurement. The response of the FIA biosensor was linear up to 1.0… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2000
2000
2012
2012

Publication Types

Select...
3
1
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…Haginoya et al determined starch damage and diastatic activity in flour by use of an FIA biosensor system comprising an oxygen electrode and an immobilized enzyme column containing glucoamylase and GOD, which were immobilized on activated aminopropyl glass beads [313]. The response of the FIA biosensor was linear up to 1.000 g L -1 glucose with a detection limit of 0.025 g L -1 .…”
Section: Wheat Flour Quality Sensormentioning
confidence: 99%
“…Haginoya et al determined starch damage and diastatic activity in flour by use of an FIA biosensor system comprising an oxygen electrode and an immobilized enzyme column containing glucoamylase and GOD, which were immobilized on activated aminopropyl glass beads [313]. The response of the FIA biosensor was linear up to 1.000 g L -1 glucose with a detection limit of 0.025 g L -1 .…”
Section: Wheat Flour Quality Sensormentioning
confidence: 99%
“…Moreover, our method can be readily automated with a flow-injection apparatus (Haginoya et al 1997), making it highly suitable for a large number of tests. From an economical point of view, the biosensor method is more convenient than the reference procedures because it uses low amounts of reagents and enzymes, inexpensive instrumentation, and unskilled operators.…”
Section: Resultsmentioning
confidence: 99%
“…Each sample was immediately stirred on a vortex mixer for 5 sec and then incubated at 40°C for 30 min. The a-amylase was first dialyzed to remove the stabilizing sugars (glucose, maltose) present in the commercial enzyme, as stated by Haginoya et al (1997) and Marconi et al (1998). Then 10.0 mL of diluted sulphuric acid (0.2%, v/v) was added to terminate the reaction and the samples were filtered (Whatman No.…”
Section: Biosensor Proceduresmentioning
confidence: 99%
See 1 more Smart Citation