1987
DOI: 10.1016/0378-4347(87)80445-0
|View full text |Cite
|
Sign up to set email alerts
|

Determination of cyclophosphamide in whole blood and plasma by reversed-phase high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
10
0

Year Published

1991
1991
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(11 citation statements)
references
References 8 publications
1
10
0
Order By: Relevance
“…Cyclophosphamide has been measured by gas chromatography (GC) with derivatisation, GC-mass spectrometry (MS) and bioassay (EI-Yazigi & Martin 1986;Juma et al 1979;Sladek et al 1984). More recent methods have used high performance liquid chromatography (HPLC), but these are difficult because of the low UV detection wavelength (200nm) and the extraction procedures necessary (Burton & James 1989;Hardy et al 1984;Rustum et al 1987).…”
Section: Discussionmentioning
confidence: 99%
“…Cyclophosphamide has been measured by gas chromatography (GC) with derivatisation, GC-mass spectrometry (MS) and bioassay (EI-Yazigi & Martin 1986;Juma et al 1979;Sladek et al 1984). More recent methods have used high performance liquid chromatography (HPLC), but these are difficult because of the low UV detection wavelength (200nm) and the extraction procedures necessary (Burton & James 1989;Hardy et al 1984;Rustum et al 1987).…”
Section: Discussionmentioning
confidence: 99%
“…Our preliminary conditions for the HPLC method were based on several previous studies, which used a mobile phase comprised of 20% acetonitrile and 80% phosphate buffer 17, 18. We found that with our initial assay conditions, substances in Ora-Plus caused peaks that overlapped with the cyclophosphamide and ifosfamide peaks.…”
Section: Discussionmentioning
confidence: 99%
“…Chromatographic data were analyzed using Shimadzu ClassVP Integrating Software v. 7.3. Our preliminary conditions were based on previously reported methods 17, 18. All chromatographic separations were obtained using a Phenomenex® Luna, 5µm, C18, 100Å, 125 × 4 mm column (Torrance, CA, USA) with a Phenomenex® Security Guard, C18, 4 × 2.0 mm guard column.…”
Section: Methodsmentioning
confidence: 99%
“…There are notable methods available, such as gas chromatography with mass detector (GC-MS) [6], high performance liquid chromatography (HPLC) [7][8][9][10][11][12], and UVspectrophotometric methods [1, 13 and 14]. Recently, Liquid chromatography with mass detector (LC-MS) methods [15][16][17][18][19][20] and UPLC-MS/MS methods [21,22], have been also been used to measure the CP in formulations and biological samples.…”
Section: Introductionmentioning
confidence: 99%