Determination of Cr(III) and Cr(VI) in water by wavelength-dispersive X-ray fluorescence spectrometry after preconcentration with an ion-exchange resin disk

Abstract: A rapid and simple method using an ion-exchange resin disk combined with wavelength-dispersive X-ray fluorescence (WDXRF) spectrometry was developed for the determination of Cr(III) and Cr(VI) in water. A 100-ml water sample was first adjusted to pH 3 with nitric acid and then passed through an anion-exchange resin disk placed on top of a cation-exchange resin disk at a flow rate of 1 ml min −1 to separate Cr(III) and Cr(VI). Anionic Cr(VI) was preconcentrated on the upper anion-exchange resin disk, whereas ca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 23 publications
(18 citation statements)
references
References 14 publications
0
18
0
Order By: Relevance
“…A 0.1 mm thick laminate film (Meiko Shokai, Japan) was used to coat the SPE disk before XRF analysis, to prevent it from being damaged by X-rays. 18,19 A Demi-Ace Model DX-15 demineralizer (Kurita Water Industries, Japan) was used to prepare deionized water. An F-52 pH meter (Horiba, Japan) was used to monitor the pH of the sample solution.…”
Section: Apparatusmentioning
confidence: 99%
See 2 more Smart Citations
“…A 0.1 mm thick laminate film (Meiko Shokai, Japan) was used to coat the SPE disk before XRF analysis, to prevent it from being damaged by X-rays. 18,19 A Demi-Ace Model DX-15 demineralizer (Kurita Water Industries, Japan) was used to prepare deionized water. An F-52 pH meter (Horiba, Japan) was used to monitor the pH of the sample solution.…”
Section: Apparatusmentioning
confidence: 99%
“…In particular, membrane disk SPEs have been used to pretreat large-volume water samples because they allow relatively high flow rates, due to their large cross-sectional areas. 16 SPE disks keep their shape during the pretreatment process to assay, so they are useful for wet analyses 17 as well as direct analyses (e.g., X-ray fluorescence (XRF) spectrometry, [18][19][20] γ-ray spectrometry, 21,22 and laser-induced breakdown spectroscopy 23 ). An analytical method using an iminodiacetate extraction disk, followed by direct introduction into GFAAS instrument, has also been reported for determining heavy metals at sub-μg L -1 levels in water.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this experiment, therefore, a 100-mL deionized water sample (pH 5.6) containing 1 mg each of Co, Ni, Cu, Cd, Sn, Pb, and Bi was passed through the conditioned IED at a flow rate of 1 mL·min -1 . The IED was then dried at 100˚C for 20 min in the electric oven, coated with a commercially available laminate film to prevent damage to the IED by X-ray irradiation [6,18], and measured using μ-EDXRF spectrometer. The mapping conditions were 100 points (1 mm diameter) in 18 × 18 mm 2 of the scanning area.…”
Section: Elemental Mappingmentioning
confidence: 99%
“…In particular, disk-type SPE has been widely used to preconcentrate a large-volume water sample (e.g., 100 -1000 mL) for inorganic [2][3][4][5][6] and organic [7][8][9][10][11] analyses because it offers higher flow rates than column-type SPE owing to its large cross-sectional area. Iminodiacetate Extraction Disks (IEDs) are useful for the preconcentration of trace metals in water because of their high selectivity for heavy metals.…”
Section: Introductionmentioning
confidence: 99%