2004
DOI: 10.1016/j.jchromb.2004.03.045
|View full text |Cite
|
Sign up to set email alerts
|

Determination of cocaine, its metabolites, pyrolysis products, and ethanol adducts in postmortem fluids and tissues using Zymark® automated solid-phase extraction and gas chromatography-mass spectrometry1

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
1

Year Published

2004
2004
2015
2015

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(11 citation statements)
references
References 45 publications
0
10
0
1
Order By: Relevance
“…In GC analysis, it is known that BE and NCOC need a derivatization step to improve its volatility due to the presence of a polar functional group in its molecular structure [28,29]. As the temperature of incubation for the chosen silylating agent, MSTFA, varies from author to author [30][31][32][33][34], the effectiveness of this derivatization procedure was evaluated using 3 different temperatures: 37, 55, and 80 • C. The main objective was to verify if cocaine chemical stability would be affected by the derivatization temperature.…”
Section: Choice Of Suitable Derivatization Temperaturementioning
confidence: 99%
“…In GC analysis, it is known that BE and NCOC need a derivatization step to improve its volatility due to the presence of a polar functional group in its molecular structure [28,29]. As the temperature of incubation for the chosen silylating agent, MSTFA, varies from author to author [30][31][32][33][34], the effectiveness of this derivatization procedure was evaluated using 3 different temperatures: 37, 55, and 80 • C. The main objective was to verify if cocaine chemical stability would be affected by the derivatization temperature.…”
Section: Choice Of Suitable Derivatization Temperaturementioning
confidence: 99%
“…Surprisingly, normorphine, an analyte rarely monitored, was detected in the next highest number of specimens (42). If free morphine was employed to identify opiate exposure, many positive specimens would be missed as only 12 of 119 contained this analyte.…”
Section: Resultsmentioning
confidence: 99%
“…Although neither is psychoactive, these biomarkers are highly effective in detecting cocaine exposure because of their long half-lives in urine. According to Lewis and coworkers, BE concentration in urine was 2–3-fold higher than EME in five postmortem cases analyzed for cocaine and metabolites by GC–MS (42). Cardona et al (43) also confirmed the presence of BE in higher concentrations than EME.…”
Section: Discussionmentioning
confidence: 99%
“…Outros trabalhos utilizando a pirólise analítica ou os produtos de pirólise para identificar a presença de drogas e seus metabólicos no sangue, na urina ou em tecidos humanos têm sido feitos [114][115][116][117][118] . Neste sentido, Mitsui et al 119 aplicaram a pirólise para estudar narcóticos e sais de alcalóides em urinas de seres humanos.…”
Section: Ciência Forenseunclassified