2011
DOI: 10.1007/s00604-011-0704-2
|View full text |Cite
|
Sign up to set email alerts
|

Determination of catecholamines based on the measurement of the metal nanoparticle-enhanced fluorescence of their terbium complexes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(18 citation statements)
references
References 48 publications
0
18
0
Order By: Relevance
“…However, the optimum pH value is 9.0, which is from the biological pH of around 7.0, so it can be considered a drawback of this method. Also, the reaction time is long enough for rapid analysis of DA [84]. Using the method, the linear dynamic ranges for analysis of DA, epinephrine and norepinephrine were 2.4-140 nM, 2.5-110 nM, and 2.8-240 nM with LODs as low as 0.42 nM, 0.25 nM, and 0.64 nM, respectively.…”
Section: Silver Nanoparticles (Agnps)mentioning
confidence: 98%
“…However, the optimum pH value is 9.0, which is from the biological pH of around 7.0, so it can be considered a drawback of this method. Also, the reaction time is long enough for rapid analysis of DA [84]. Using the method, the linear dynamic ranges for analysis of DA, epinephrine and norepinephrine were 2.4-140 nM, 2.5-110 nM, and 2.8-240 nM with LODs as low as 0.42 nM, 0.25 nM, and 0.64 nM, respectively.…”
Section: Silver Nanoparticles (Agnps)mentioning
confidence: 98%
“…[30], but a little higher than that reported in Ref. [31]. However, our method was conducted in a neutral buffer solution, which was close to the pH value of biological fluids.…”
Section: Interference Of Coexisting Foreign Substancesmentioning
confidence: 83%
“…The detection limit was 94 nM. Kim et al [31] developed a fluorescence method for determining DA by using AgNPs-enhanced fluorescence of Tb 3 þ in alkaline solution. In this work, a facile and sensitive method for the determination of DA was proposed based on Tb 3 þ -Y 3 þ -DA co-luminescence sensitized by AgNPs in neutral aqueous solution.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Lots of methods had been developed, such as spectrophotometry [13,14], ion chromatography [15], fluorescence spectroscopy [16], gas chromatography [17], capillary electrophoresis [18], high performance liquid chromatography (HPLC) [19,20] and electrochemical assay [21][22][23][24]. Among them, electrochemical assay is more reliable and simple due to NE's electroactivity itself [3].…”
Section: Introductionmentioning
confidence: 99%