Determination of carnitine and acylcarnitines in urine by high-performance liquid chromatography–electrospray ionization ion trap tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
59
0

Year Published

2004
2004
2017
2017

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 80 publications
(65 citation statements)
references
References 28 publications
5
59
0
Order By: Relevance
“…Signals were preliminarily filtered by P < 0.05 and up-/downregulation factor (lower than −30% or higher than +30%) and manually processed to eliminate spurious peaks. The accurate mass list was searched against the METLIN web-based algorithm (50,51) (52), and, whenever possible, accurate MS/MS data, following the indications on MS/MS fragmentation patterns available in the literature (53)(54)(55)(56). The lipid species annotated are reported in SI Appendix, Table S1 (positive ion mode) and SI Appendix, Table S2 (negative ion mode).…”
Section: Methodsmentioning
confidence: 99%
“…Signals were preliminarily filtered by P < 0.05 and up-/downregulation factor (lower than −30% or higher than +30%) and manually processed to eliminate spurious peaks. The accurate mass list was searched against the METLIN web-based algorithm (50,51) (52), and, whenever possible, accurate MS/MS data, following the indications on MS/MS fragmentation patterns available in the literature (53)(54)(55)(56). The lipid species annotated are reported in SI Appendix, Table S1 (positive ion mode) and SI Appendix, Table S2 (negative ion mode).…”
Section: Methodsmentioning
confidence: 99%
“…Vernez et al [60] employed cation-exchange SPE of acidified urine as their sample cleanup. Subsequent ion-pairing RP-HPLC (Phenomenex LUNA 15062.0 mm, 5 mm) with 10 mM heptafluorobutric acid and 10 mM ammonium acetate aqueous mobile phase gradient-eluted from 20% to 90% methanol with MS n detection (positive-ion mode, 4.0 kV, N 2 sheath gas, 3007C capillary) afforded quantitation of free carnitine and acylcarnitines.…”
Section: Carnitinesmentioning
confidence: 99%
“…Liquid chromatographyelectrospray mass spectrometry (LC-ESI-MS) has emerged as a sensitive analytical technique for the determination of various compounds (Grace et al, 2003;Bogialli et al, 2003;Vernez et al, 2003;Zhang et al, 2005;Fuh et al, 2004). The aim of this investigation is to develop a LC-ESI-MS method incorporated with microdialysis technique to determine sinomenine and study the pharmacokinetics of free-form sinomenine in rat skin.…”
Section: Introductionmentioning