The 4TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND SCIENCE EDUCATION (ICoMSE) 2020: Innovative Research in Science and Mathema 2021
DOI: 10.1063/5.0043135
|View full text |Cite
|
Sign up to set email alerts
|

Determination of carbohydrates content in red dragon fruit for food chemistry laboratory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 8 publications
0
2
0
Order By: Relevance
“…At this point, the sample is treated with HCl to hydrolyse starch into monosaccharides and neutralize the pH. The pH must be conditioned in this Luff Schoorl carbohydrate test (Fitra et al 2020;Kurnia et al 2021) because if the pH is too low (too acidic), the results will be higher than they are, and if the pH is too high (too alkaline), the solution used to neutralize HCl will be NaOH, and vice versa. After destroying the samples, a solution of Luff schoorl and H2SO4 is added to bind copper ions formed from the reduction of monosaccharides, forming CuSO4, and then KI indicator is added to test the sensitivity to iodine from the dark blue dye created by starch indicator.…”
Section: Resultsmentioning
confidence: 99%
“…At this point, the sample is treated with HCl to hydrolyse starch into monosaccharides and neutralize the pH. The pH must be conditioned in this Luff Schoorl carbohydrate test (Fitra et al 2020;Kurnia et al 2021) because if the pH is too low (too acidic), the results will be higher than they are, and if the pH is too high (too alkaline), the solution used to neutralize HCl will be NaOH, and vice versa. After destroying the samples, a solution of Luff schoorl and H2SO4 is added to bind copper ions formed from the reduction of monosaccharides, forming CuSO4, and then KI indicator is added to test the sensitivity to iodine from the dark blue dye created by starch indicator.…”
Section: Resultsmentioning
confidence: 99%
“…The crude fat, crude protein, total ash, and moisture content were analyzed using a standard method of AOAC (2012). The carbohydrate content was analyzed using the Luff Schoorl method that was following the Indonesian National Standard procedure (SNI 01‐2891‐1992) as described in Kurnia et al (2021). The pH was recorded using Metrohm 827 pH lab analysis (Metrohm Ltd, Switzerland), and a w was recorded using a w meter AQUA LAB 4TE (METER Group Inc, USA).…”
Section: Methodsmentioning
confidence: 99%