1999
DOI: 10.1016/s0378-4347(99)00214-5
|View full text |Cite
|
Sign up to set email alerts
|

Determination of busulfan in human plasma using high-performance liquid chromatography with pre-column derivatization and fluorescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0
1

Year Published

2010
2010
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(14 citation statements)
references
References 17 publications
0
13
0
1
Order By: Relevance
“…28 Busulfan plasma concentrations from Lyon were measured by HPLC with UV detection for data before 2010, 29 and by an updated, cross-validated liquid chromatography – tandem mass spectrometry method after 2010. 30 All the assays used were linear from 20 to 2000 ng/mL with an interday imprecision of <10%.…”
Section: Methodsmentioning
confidence: 99%
“…28 Busulfan plasma concentrations from Lyon were measured by HPLC with UV detection for data before 2010, 29 and by an updated, cross-validated liquid chromatography – tandem mass spectrometry method after 2010. 30 All the assays used were linear from 20 to 2000 ng/mL with an interday imprecision of <10%.…”
Section: Methodsmentioning
confidence: 99%
“…LC-MS/MS is the most preferred method for measuring busulfan in a pediatric setting because of its benefits over other methods. GC-based methods and LC-fluorescence/UV techniques are time-consuming and laborious, requiring derivatization steps for preparation and a large quantity of plasma of up to 1 mL, along with a long analysis time of up to 30 min per run [10-13]. The recently developed ELISA-based automated method shows similar precision, required time, and sample volume compared with previously described methods, while having the risk of cross-reactivity and lot-to-lot variability of reagents [14].…”
Section: Discussionmentioning
confidence: 99%
“…Gas chromatography (GC) coupled with electron capture detector [10] or mass spectrometry (MS) [11], liquid chromatography (LC) coupled with UV detectors [12] or fluorescence detectors [13] have been introduced, and an ELISA-based automated method was developed recently [14]. Among the existing methods, LC coupled with MS [15, 16] or with tandem MS (MS/MS) [17, 18] offers a high level of sensitivity and requires a small sample volume, which is beneficial in a pediatric setting.…”
Section: Introductionmentioning
confidence: 99%
“…Different analytical methods have been developed for busulfan measurement in plasma and other biological fluids, including GC and GC-MS [4][5][6][7], HPLC with UV detection [8][9][10], and with fluorescence detection [11,12] and LC-MS [13,14]. In the present study, we compared two published methods: (1) a rapid and accurate LC-MS assay with SIM mode, (2) a sensitive HPLC-FL assay using 2-naphthalenethiol derivatization for the busulfan quantitation.…”
Section: Introductionmentioning
confidence: 99%