1997
DOI: 10.1093/jat/21.6.406
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Buprenorphine in Human Plasma by Gas Chromatography-Positive Ion Chemical Ionization Mass Spectrometry and Liquid Chromatography-Tandem Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
37
0

Year Published

2002
2002
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 67 publications
(40 citation statements)
references
References 23 publications
3
37
0
Order By: Relevance
“…Following up to 8 mg sublingual buprenorphine, peak plasma concentrations rarely exceed 10 ng/ml (0.021 M) (16 -18) and can reach subnanogram-per-milliliter concentrations within 24 h of even higher doses (19,20). It is therefore important that sensitive methods be employed for pharmacokinetic and safety studies on buprenorphine.…”
Section: Elsevier Science (Usa)mentioning
confidence: 99%
“…Following up to 8 mg sublingual buprenorphine, peak plasma concentrations rarely exceed 10 ng/ml (0.021 M) (16 -18) and can reach subnanogram-per-milliliter concentrations within 24 h of even higher doses (19,20). It is therefore important that sensitive methods be employed for pharmacokinetic and safety studies on buprenorphine.…”
Section: Elsevier Science (Usa)mentioning
confidence: 99%
“…This very low concentration level constitutes a challenging task for analysis. 5 There were various analytical methods for BP in biological specimens, such as gas chromatography (GC), 6 gas chromatography-mass spectrometry (GC-MS), [8][9][10] high-performance liquid chromatography(HPLC) 7 and high-performance liquid chromatography-mass spectrometry (HPLC-MS).…”
Section: Introductionmentioning
confidence: 99%
“…But many methods had no reported assay validation or incomplete assay validation, and could not perform simultaneous determination of BP, NBP and NLX in human plasma. 1,[3][4][5]9 A rapid and simultaneous method for determination of BP, NBP and NLX in human plasma by UPLC-MS/MS was established. The method optimized the parameters of SPE and other UPLC-MS/MS parameters, so that can get the good recoveries and little interference.…”
Section: Introductionmentioning
confidence: 99%
“…Many chromatographic techniques were proposed for the determination of BU and its metabolite norbuprenorphine (NBU) in biological matrices, from HPLC with coulometric detection (12), liquid chromatography-mass spectrometry coupling (LC-MS) (13,14), and gas chromatography -mass spectrometry (GC-MS) (12,14). Mass spectrometry is very often used as it fulfills the requirement of specificity necessary for forensic investigations (unexplained deaths, buprénorphine abuse, etc.…”
Section: Introductionmentioning
confidence: 99%
“…), and because of its high sensitivity, very useful for the determination of this low-concentration drug. Most of the methods employing mass spectrometry yielded LLOQ between 0.1 ng/ml (13) and 0.5 ng/ml (14). One peculiarity of treatments with HD-BU is that their efficacy can be checked using toxicological analyses, most often by screening urine samples for drugs of abuse using immunoassays then confirming the positive samples with mass spectrometry.…”
Section: Introductionmentioning
confidence: 99%