1991
DOI: 10.1021/ac00005a013
|View full text |Cite
|
Sign up to set email alerts
|

Determination of benzo[a]pyrene sulfate conjugates from benzo[a]pyrene-treated cells by continuous-flow fast atom bombardment mass spectrometry

Abstract: The level of certain water-soluble hydrocarbon conjugates, such as benzo[a]pyrene sulfates (BP-SO4), is a direct measure of carcinogenic polycyclic aromatic hydrocarbon metabolism and an indication of exposure. A new method, based on continuous-flow high-resolution fast atom bombardment mass spectrometry, has been developed for the analysis of BP-SO4 in the medium of cell cultures treated with benzo[a]pyrene. An organic solvent extract of medium from cultures of the human hepatoma cell line (HepG2) was fractio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
1
0

Year Published

1991
1991
1994
1994

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(1 citation statement)
references
References 28 publications
(23 reference statements)
0
1
0
Order By: Relevance
“…The moving belt interface has been used to observe analytes in high percentages of water [20] and has been used for detection in the picogram range [15], but it can have memory effects, and some workers consider it cumbersome [6). Other techniques, such as thermospray [21][22][23], electrospray [24][25][26], and flow FAB [27][28][29], are used as on-line continuous LC interfaces, but they typically produce "CI-like" mass spectra and give little structural information. In the past few years, however, experiments using electrospray [30] and thermospray [31] have been conducted using collision-activated dissociation for improved structural analysis.…”
mentioning
confidence: 99%
“…The moving belt interface has been used to observe analytes in high percentages of water [20] and has been used for detection in the picogram range [15], but it can have memory effects, and some workers consider it cumbersome [6). Other techniques, such as thermospray [21][22][23], electrospray [24][25][26], and flow FAB [27][28][29], are used as on-line continuous LC interfaces, but they typically produce "CI-like" mass spectra and give little structural information. In the past few years, however, experiments using electrospray [30] and thermospray [31] have been conducted using collision-activated dissociation for improved structural analysis.…”
mentioning
confidence: 99%