Determination of arsenic by anodic stripping voltammetry and differential pulse anodic stripping voltammetry

Abstract: Figure 3. Correspondence of results obtained with the column RIA procedure and the dextran-coated charcoal method patients on digitoxin therapy is immunologically indistinguishable from the digitoxin in the standards. In other words, the antibody recognizes the digitoxin in clinical specimens and standards as identical. As shown in Table II, acceptable results were obtained in a parallelism study over a sixfold range of dilution. These data indicate that various components in the serum, including potentially c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

3
123
1
6

Year Published

1998
1998
2011
2011

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 229 publications
(139 citation statements)
references
References 27 publications
3
123
1
6
Order By: Relevance
“…This same conclusion was reached by Forsberg^^. (21), who performed differential pulse ASV as well. These workers found Hg and Ag to be completely unsatisfactory as electrodes.…”
supporting
confidence: 69%
See 3 more Smart Citations
“…This same conclusion was reached by Forsberg^^. (21), who performed differential pulse ASV as well. These workers found Hg and Ag to be completely unsatisfactory as electrodes.…”
supporting
confidence: 69%
“…The stripping peak at 0,2 V is therefore due to the stripping of As in the outer As layers ( , As stripped from an As substrate), while the peak at 0.5 Vis due to the stripping of the As in the first 1-2 monolayers. The observation of one and two stripping peaks has been reported in the determination of arsenic by anodic stripping voltammetry (19,21).…”
Section: E Macroscopically Nonhomogeneous Surfacementioning
confidence: 88%
See 2 more Smart Citations
“…In particular, gold was found to be the superior substrate as a working electrode for arsenic determination [20,29,30], because it provides a more sensitive response toward arsenic oxidation than other electrode materials and has a higher hydrogen overvoltage than platinum [31,32]. Problems occurring with solid electrodes include the dependence of their response on pre-treatment and the formation of oxide films, which limits sensitivity and reproducibility and, as a consequence, their use for routine applications [23,33].…”
Section: Introductionmentioning
confidence: 99%