1999
DOI: 10.1016/s0003-2670(99)00242-1
|View full text |Cite
|
Sign up to set email alerts
|

Determination of arsenic and vanadium in airborne related reference materials by inductively coupled plasma–mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0
1

Year Published

2006
2006
2018
2018

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 33 publications
(20 citation statements)
references
References 29 publications
0
18
0
1
Order By: Relevance
“…The EF of As ranged from 1.2 to 60, with an average value of 8.0 ± 8.0. Release of As bearing particles from coal combustion facilities has been well documented by many researchers (Wang et al, 1999;Okuda et al, 2008). It should also be mentioned that, lignite and fly ash samples collected from the Megalopolis power plant A, as well as bulk deposition samples collected from sites in the Megalopolis city were, among other elements, enriched in As (Papaefthymiou et al, 2007;Papaefthymiou, 2008).…”
Section: Seasonal Variation Of the Analyzed Parametersmentioning
confidence: 88%
“…The EF of As ranged from 1.2 to 60, with an average value of 8.0 ± 8.0. Release of As bearing particles from coal combustion facilities has been well documented by many researchers (Wang et al, 1999;Okuda et al, 2008). It should also be mentioned that, lignite and fly ash samples collected from the Megalopolis power plant A, as well as bulk deposition samples collected from sites in the Megalopolis city were, among other elements, enriched in As (Papaefthymiou et al, 2007;Papaefthymiou, 2008).…”
Section: Seasonal Variation Of the Analyzed Parametersmentioning
confidence: 88%
“…A number of analytical procedures have been reported for the determination of vanadium including atomic absorption spectrometry (AAS) [6,7], inductively coupled plasma-atomic emission spectrometry (ICP-AES) [8,9], inductively coupled plasma-MS (ICP-MS) [10,11], GC [12,13] and LC [14 -17]. AAS suffers from low sensitivity [6], while ICP-AES and quadruple ICP-MS [10] may be subjected to matrix interferences.…”
Section: Introductionmentioning
confidence: 99%
“…AAS suffers from low sensitivity [6], while ICP-AES and quadruple ICP-MS [10] may be subjected to matrix interferences. The determination of vanadium species in the environmental samples has been reviewed in Refs.…”
Section: Introductionmentioning
confidence: 99%
“…For this reason, a two-step digestion procedure was used in this research. In the first step, 10 mg samples were digested with 5 ml of HClO 4 + 3 ml of HNO 3 + 2 ml of HF in sealed vessels and heated in a pressure bomb at 170 • C for 5 h [14,15]. In the second step, the sample solutions after digestion were transferred into a PTFE beaker and gently heated (90 • C) on a hot plate to evaporate the residual acid.…”
Section: Analytical Technique and Equipmentmentioning
confidence: 99%