2012
DOI: 10.1016/j.jpba.2012.06.014
|View full text |Cite
|
Sign up to set email alerts
|

Determination of amlodipine in human plasma using automated online solid-phase extraction HPLC–tandem mass spectrometry: Application to a bioequivalence study of Chinese volunteers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(20 citation statements)
references
References 8 publications
0
20
0
Order By: Relevance
“…Concentration of levamlodipine in human plasma showed good linear relationship within 0.05 ~ 10 µg × L − 1 . The relative standard deviation (RSD) values of intra-and interday precision were both less than 10%; and endogenous substances do not interfere with the determination of levamlodipine [9]. C max , AUC 0 − t and AUC 0−∞ were transformed by logarithm and analyzed by variance.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Concentration of levamlodipine in human plasma showed good linear relationship within 0.05 ~ 10 µg × L − 1 . The relative standard deviation (RSD) values of intra-and interday precision were both less than 10%; and endogenous substances do not interfere with the determination of levamlodipine [9]. C max , AUC 0 − t and AUC 0−∞ were transformed by logarithm and analyzed by variance.…”
Section: Discussionmentioning
confidence: 99%
“…Data collection and handling was employed with Analyst 1.6.3 software (Applied Biosystems, Foster City, CA, U.S.A.). The solid-phase extraction (SPE) experiments [9] were performed by HLB 96-well Plate (Waters Oasis, WAT058951). The plate contains a reversed phase functionalized polymeric sorbent (30 mg/well), in which particle size is 30 μm.…”
Section: Bioanalysismentioning
confidence: 99%
“…According to Shentu et al. , method recovery was evaluated by comparing the peak area of QC samples to standards in water ( n = 3).…”
Section: Methodsmentioning
confidence: 99%
“…The sample pretreatment methods were complicated and time consuming, and only tested diazepam and its free metabolites: nordazepam, oxazepam, and temazepam. Recently, online SPE technology has received an increasing amount of attention by analysts and widely applied to forensic toxicological analysis . Online SPE not only overcomes the shortcoming of offline SPE, but also avoids human errors.…”
Section: Introductionmentioning
confidence: 99%
“…Several methods are available in the literature to measure the concentration of VS and AM in individual and combined products (21)(22)(23). The method was validated for parameters like system suitability, selectivity, linearity, range, precision, accuracy, and robustness.…”
Section: Methods Validationmentioning
confidence: 99%