1984
DOI: 10.1021/ac00272a020
|View full text |Cite
|
Sign up to set email alerts
|

Determination of aldicarb, aldicarb oxime, and aldicarb nitrile in water by gas chromatography/mass spectrometry

Abstract: A technique for the analysis of aldicarb and two of Its degradation products Is described. The use of a short capillary column coupled to a mass spectrometer Is found to facilitate the analysis of the thermally labile carbamate pesticide. Methane and Isobutane chemical Ionization reagent gases are evaluated. The limits of detection for aldicarb, aldicarb oxime, and aldicarb nitrile are 0.3 ng, 1.2 ng, and 0.15 ng, respectively. Application of the technique to the study of the fate of aldicarb In anaerobic grou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
19
0

Year Published

1986
1986
2005
2005

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 51 publications
(22 citation statements)
references
References 22 publications
3
19
0
Order By: Relevance
“…Aldicarb has the structure of an oxime carbamate and the major product of its thermal degradation is the corresponding nitrile [5].…”
Section: Carbamate Reactivity In Gcmentioning
confidence: 99%
See 2 more Smart Citations
“…Aldicarb has the structure of an oxime carbamate and the major product of its thermal degradation is the corresponding nitrile [5].…”
Section: Carbamate Reactivity In Gcmentioning
confidence: 99%
“…Several special devices have been designed to minimise the decomposition of thermally labile compounds in GC (short columns [4,5]; programmed temperature vaporizer devices [4,6]; low pressure GC [7], and supersonic GC [8]). Several reports have studied the photodegradation of such pesticides [9,10].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the upper portion (a), the sample is introduced either through a Varian (Walnut Creek, CAl 3400 GC (4) or through our homemade GC injector (3) and is transferred through a 50-cm-Iong megabore capillary column (5) to the supersonic nozzle (6). The nozzle flow is supplied by both needle values V 1 and V 2 • The supersonic beam (homemade) nozzle is an all ceramic or Vespel " nozzle which was heated separately.…”
Section: A Ms 108mbmentioning
confidence: 99%
“…All these pesticides are incompatible with standard GC-MS analysis [13,14] and thus they require fast GC-MS [2,3], particle beam LC-MS [13][14][15], electrospray LC-MS [25], or thermospray LC-MS [26] methods for analysis . It is clearly observed that with very fast GC-MS (Figure 3a) with a speed enhancement factor of 100, all these compounds were successfully analyzed and a reasonable GC separation was obtained.…”
Section: Fast Gc-ms Analysis Of Carbamate Pesticidesmentioning
confidence: 99%