2021
DOI: 10.1007/s10967-021-07622-1
|View full text |Cite
|
Sign up to set email alerts
|

Determination of 239Pu in urine by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) using an automated offline sample preparation technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 19 publications
1
3
0
Order By: Relevance
“…Furthermore, this impurity test also demonstrated that no observed organic compounds in the urine matrix could interfere with the five actinides. The breakdown of organic materials in the urine matrix by acid digestion thus extended the life span of separation columns, which was further verified in a recent study by Xiao and Jones …”
Section: Resultssupporting
confidence: 58%
See 1 more Smart Citation
“…Furthermore, this impurity test also demonstrated that no observed organic compounds in the urine matrix could interfere with the five actinides. The breakdown of organic materials in the urine matrix by acid digestion thus extended the life span of separation columns, which was further verified in a recent study by Xiao and Jones …”
Section: Resultssupporting
confidence: 58%
“…The breakdown of organic materials in the urine matrix by acid digestion thus extended the life span of separation columns, which was further verified in a recent study by Xiao and Jones. 28 The successful separation of ultratrace actinides using extraction chromatography is related to column efficiency, which is reported as the number (N) of theoretical plates. The greater the number of theoretical plates, the better the potential resolving power of the column.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…But it was difficult to accurately control the flow rate in this gas pressure mode. A prepFAST MC chromatography system [11] was launched by Elemental Scientific (ESI Omaha, NE, USA) for isotopic sample preparation [12][13][14][15][16][17][18]. It used a syringe system to drive the eluent through the column and enabled precise control over the eluent flow rate.…”
Section: Introductionmentioning
confidence: 99%
“…Online SPE–ICP–MS is an automatic sequential analytical technology characterized by good repeatability and high-speed data acquisition. By virtue of these advantages, coupled SPE–ICP–MS systems have been widely employed to monitor environmental radioactivity. For radionuclide analysis, this coupled system provides radiological protection to operators by suppressing the exposure dose. For example, the system is useful for monitoring radioactivity during the decommissioning of nuclear power plants.…”
Section: Introductionmentioning
confidence: 99%