2002
DOI: 10.1039/b201803a
|View full text |Cite
|
Sign up to set email alerts
|

Determination of 236U/238U isotope ratio in contaminated environmental samples using different ICP-MS instruments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
48
2
4

Year Published

2002
2002
2016
2016

Publication Types

Select...
8
2

Relationship

2
8

Authors

Journals

citations
Cited by 79 publications
(54 citation statements)
references
References 35 publications
0
48
2
4
Order By: Relevance
“…Thus, the initial abundance sensitivity for the 236 U/ 238 U isotope ratio was about 40-fold worse than the value achieved in quadrupole-based ICP-MS without a collision cell. 25 Nevertheless, ion beam moderation in the collision cell improved the abundance sensitivity by almost 400 times.…”
Section: Abundance Sensitivity In Icp-cc-qmsmentioning
confidence: 99%
“…Thus, the initial abundance sensitivity for the 236 U/ 238 U isotope ratio was about 40-fold worse than the value achieved in quadrupole-based ICP-MS without a collision cell. 25 Nevertheless, ion beam moderation in the collision cell improved the abundance sensitivity by almost 400 times.…”
Section: Abundance Sensitivity In Icp-cc-qmsmentioning
confidence: 99%
“…35 This abundance sensitivity of sector field instruments is less than that of quadrupole instruments. 36 The average concentration of stable strontium in urine was experimentally determined to be approximately 5 mg L 21 ; abundance sensitivity was studied at medium mass resolution (m/Dm~4450) using a standard solution with concentration of 1 mg mL 21 of strontium. In order to correct for possible interferences, intensity was measured at the masses m ¡ 0.5 u, m ¡ 1.5 u, m ¡ 2.5 u, etc.…”
Section: Abundance Sensitivitymentioning
confidence: 99%
“…182 Further on, a large number of publications covers the field of radionuclide determination applying sector field devices, making use of the high sensitivity, the isotope ratio capabilities (even at large ratios) and the application of high mass resolution. [194][195][196][197][198] A review of Ketterer and Szechenyi shows how ICP-SFMS has become one of the most popular methods for the routine and high-throughput determination of plutonium and other transuranic elements because of its speed of analysis, simplicity of sample preparation, straightforward operation, sensitivity, low background and ability to resolve interfering polyatomic ions. 199 Lariviere et al 200 used the high sensitivity of ICP-SFMS for the rapid and automated sequential determination of ultra-trace long-lived actinides in air filters.…”
Section: Geological and Radionuclide Applicationsmentioning
confidence: 99%