2011
DOI: 10.1016/j.ab.2011.07.016
|View full text |Cite
|
Sign up to set email alerts
|

Detection of vaccinia virus DNA by quartz crystal microbalance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
29
0
2

Year Published

2013
2013
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(32 citation statements)
references
References 34 publications
0
29
0
2
Order By: Relevance
“…Hereby, some of the most promising results of DNA-QCM biosensors for different viruses are discussed. For instance, DNA-QCM biosensors have been successfully tested for the detection of hepatitis B virus (HepBV) [105][106][107], hepatitis C virus (HepCV) [117], vaccinia virus [108], viral haemorrhagic septicaemia virus (VHSV) [109], human papilloma virus (HPV) [110], dengue virus [118], and orchid viruses such as cymbidium mosaic virus (CymMV) and odontoglossum ringspot virus (ORSV) [111].…”
Section: Dna and Aptamers For Qcm Virus Sensorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Hereby, some of the most promising results of DNA-QCM biosensors for different viruses are discussed. For instance, DNA-QCM biosensors have been successfully tested for the detection of hepatitis B virus (HepBV) [105][106][107], hepatitis C virus (HepCV) [117], vaccinia virus [108], viral haemorrhagic septicaemia virus (VHSV) [109], human papilloma virus (HPV) [110], dengue virus [118], and orchid viruses such as cymbidium mosaic virus (CymMV) and odontoglossum ringspot virus (ORSV) [111].…”
Section: Dna and Aptamers For Qcm Virus Sensorsmentioning
confidence: 99%
“…These range from ions [122,123] or small molecules [124] to a wide range of proteins [125] or even entire cells [126,127]. As a result, aptamers Kleo et al [108] fabricated a DNA-QCM biosensor for indirect determination of vaccinia virus DNA using polymerase chain reaction (PCR) amplification. The biotinylated-capture-DNA was immobilized via affinity binding to NeutrAvidin, while NeutrAvidin was anchored to the QCM electrode by thiol moieties.…”
Section: Aptamersmentioning
confidence: 99%
“…However, these are still expensive due to the need for specialist equipment and staff [93][94]. PCR based methods also do not always correctly amplify viral nucleic acids when the viral concentration in samples is at a critically low level [95].…”
Section: Virus Detection and Viral Biosensing Systemsmentioning
confidence: 99%
“…If the analytical signal is too weak to detect target materials, the detection sensitivity can be increased by introducing the signalenhancing step (Kurosawa et al, 2006). QCMI shows high detection sensitivity for biological materials even viruses (Bachelder et al, 2005;Eun et al, 2002;Kleo et al, 2011;Lee and Chang, 2005;Owen et al, 2007;Su et al, 2003;Susmel et al, 2000;Uttenthaler et al, 2001). Because a detection instrument for QCM is potable and QCM coated with virus-specific antibodies to detect plant viruses has long life span, it can be used for on site detection of plant viruses (Becker and Cooper, 2011;Eun et al, 2002).…”
Section: Quartz Crystal Microbalance Immunosensors (Qcmi)mentioning
confidence: 99%