2018
DOI: 10.7567/jjap.57.07lf05
|View full text |Cite
|
Sign up to set email alerts
|

Detection of unstable plaque phantom by ultrasonic velocity-change imaging method under cold exposure

Abstract: We have investigated the ultrasonic velocity-change (UVC) imaging method to detect unstable vessel plaques using the difference in the temperature coefficient of ultrasonic velocity between water and fat. Thus far, to obtain effective ultrasonic velocity changes in the UVC imaging method, a warming procedure using a laser or an ultrasonic wave has been used. In this study, we utilize a cooling procedure instead of the warming procedure for this imaging method. As a result, lipid areas inside a carotid artery p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

1
10
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 27 publications
1
10
0
Order By: Relevance
“…So far, although several phantoms for MRI apparatus based on agarose have been fabricated and evaluated, 35,36) there is no phantom considering dual use with the ultrasound device. In general, any phantom is used not only for cartilage evaluation but also for other applications such as the detection of vulnerable plaque 37) and treatment evaluation, 38) and is also useful for the performance evaluation of conventional equipment and the verification of new methods.…”
Section: Introductionmentioning
confidence: 99%
“…So far, although several phantoms for MRI apparatus based on agarose have been fabricated and evaluated, 35,36) there is no phantom considering dual use with the ultrasound device. In general, any phantom is used not only for cartilage evaluation but also for other applications such as the detection of vulnerable plaque 37) and treatment evaluation, 38) and is also useful for the performance evaluation of conventional equipment and the verification of new methods.…”
Section: Introductionmentioning
confidence: 99%
“…In the related experiment, we succeeded in finding the fat region in the carotid artery phantom. [19][20][21][22] At the present stage, however, the success rate of finding an appropriate UVC image is low because of the fluctuation of the echo path caused by motion, such as a heartbeat. Therefore, we have proposed a method to remove the influence of motion in the UVC method.…”
mentioning
confidence: 98%
“…[8][9][10][11][12] We have investigated a non-invasive method to identify lipid areas in the human body using the ultrasonic velocitychange (UVC) method. [13][14][15][16][17][18][19][20][21][22] The UVC method is based on the fact that the temperature dependence of ultrasonic velocity depends on the medium where ultrasonic waves propagate. Around body temperature, the temperature change rate of ultrasonic velocity in water is +1.9 m • s −1 • °C−1 and that in fat is −4.9 m • s −1 • °C−1 .…”
mentioning
confidence: 99%
See 2 more Smart Citations