2002
DOI: 10.1021/ac011031v
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Ultratrace Phosphorus and Sulfur by Quadrupole ICPMS with Dynamic Reaction Cell

Abstract: A method of detection of ultratrace phosphorus and sulfur that uses reaction with O2 in a dynamic reaction cell (DRC) to oxidize S+ and P+ to allow their detection as SO+ and PO+ is described. The method reduces the effect of polyatomic isobaric interferences at m/z = 31 and 32 by detecting P+ and S+ as the product oxide ions that are less interfered. Use of an axial field in the DRC improves transmission of the product oxide ions 4-6 times. With no axial field, detection limits (3sigma, 5-s integration) of 0.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
183
3
2

Year Published

2002
2002
2018
2018

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 173 publications
(190 citation statements)
references
References 13 publications
(15 reference statements)
2
183
3
2
Order By: Relevance
“…The 32 S 16 O detection limit was similar to the detection limits obtained by using other hyphenated ICPMS techniques for S detection. 24,25 Also, the detection limit of 32 S under the Xe gas mode was also similar to previously reported values. 12,19 Taking into account the sample volume of 2.0 μL, in ICPMS under O2 gas mode the absolute detection limits for vasopressin, oxytocin, and amyloid β were 65, 77, and 110 fmol, respectively.…”
Section: Hyphenation Of Nano Hplc and Icpmssupporting
confidence: 90%
“…The 32 S 16 O detection limit was similar to the detection limits obtained by using other hyphenated ICPMS techniques for S detection. 24,25 Also, the detection limit of 32 S under the Xe gas mode was also similar to previously reported values. 12,19 Taking into account the sample volume of 2.0 μL, in ICPMS under O2 gas mode the absolute detection limits for vasopressin, oxytocin, and amyloid β were 65, 77, and 110 fmol, respectively.…”
Section: Hyphenation Of Nano Hplc and Icpmssupporting
confidence: 90%
“…A formação de um novo íon a ser monitorado também é possível, tal como exemplificado na determinação de S e P monitorando SO + e PO + , respectivamente. 42 Essas abordagens podem ser exploradas para a minimização do BG intrínseco à técnica, bem como para superar interferências.…”
Section: Figura 3 Separação Temporal Do Sinal Analítico E Intenso Bgunclassified
“…[30][31][32] Oxygenation is an effective way of avoiding spectral interferences by producing an oxide ion free from interfering molecular ions or by oxygenating the isobaric interfering ions. [33][34][35][36][37][38][39][40][41][42][43] However, the effectiveness of O2 has not been evaluated sufficiently and the underlying mechanism of oxygenation in the reaction cell has not been fully elucidated, although the mechanisms underlying the use of NH3 and CH4 have been discussed by several researchers. We investigated the mechanism of oxygenation by using the bond energy and the enthalpy change (ΔH) between the ions and O, and demonstrated the usefulness of theoretical calculations for elucidating reaction mechanisms in DRCs.…”
Section: Introductionmentioning
confidence: 99%