1977
DOI: 10.1016/0005-2728(77)90161-x
|View full text |Cite
|
Sign up to set email alerts
|

Detection of the kinetics of biochemical reactions with oxygen using exchange broadening in the ESR spectra of nitroxide radicals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
71
0

Year Published

1982
1982
2017
2017

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 96 publications
(71 citation statements)
references
References 2 publications
0
71
0
Order By: Relevance
“…1, are described not only to illustrate features of the instrument but also because this is a widely used compound for spin-label oximetry. In an early paper, Backer et al [19] used the resolution of the superhyperfine structure of compound II (4-carboxy-2.2.5.5-tetramethyl-3-imidazoline-3-oxide-1-oxyl) of Fig. 1 as an indicator of bimolecular collisions with dissolved O 2 .…”
Section: Spin-label Oximetrymentioning
confidence: 99%
“…1, are described not only to illustrate features of the instrument but also because this is a widely used compound for spin-label oximetry. In an early paper, Backer et al [19] used the resolution of the superhyperfine structure of compound II (4-carboxy-2.2.5.5-tetramethyl-3-imidazoline-3-oxide-1-oxyl) of Fig. 1 as an indicator of bimolecular collisions with dissolved O 2 .…”
Section: Spin-label Oximetrymentioning
confidence: 99%
“…An advantage of EPR oximetry is that it is based on pure physical interaction, Heisenberg spin exchange, between paramagnetic molecules of probe and oxygen, and does not interfere with oxygen metabolism, therefore providing a basis for noninvasive oxygen measurements in biological systems. Initially, the paramagnetic probes for EPR oximetry were almost exclusively nitroxides (Backer et al, 1977;Lai et al, 1982;Froncisz et al, 1985;Bacic et al, 1989;Chan et al, 1989;Hyde & Subszynski, 1989). Both the longitudinal (T1) and transverse (T2) relaxation times of the NRs can be affected by collisions of the nitroxide with dissolved oxygen.…”
Section: Epr-based Oximetric Applications Of the Nitroxidesmentioning
confidence: 99%
“…The first observation of oxygen-induced NR broadening in various solvents was reported by Povich (Povich, 1975). Two years later the T2 oximetry method was proposed and applied to follow mitochondrial respiration in samples containing about 100 liver cells (Backer et al, 1977). T1-sensitive EPR oximetry was developed by Hyde et al (Froncisz et al, 1985;Hyde et al, 1990).…”
Section: Epr-based Oximetric Applications Of the Nitroxidesmentioning
confidence: 99%
See 1 more Smart Citation
“…With a suitable spin probe, this property can be used to quantitate 02 concentrations in solution (8)(9)(10).…”
mentioning
confidence: 99%