2021
DOI: 10.1101/2021.09.15.21263644
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Detection of SARS-CoV-2 in the community by nucleic acid amplification testing of saliva

Abstract: Efficient wide-scale testing for SARS-CoV-2 is crucial for monitoring the incidence of the infection in the community. The gold standard for COVID-19 diagnosis is the molecular analysis of epithelial secretions from the upper respiratory system captured by nasopharyngeal (NP) swabs, which requires the intervention of trained personnel. Given the ease of collection, saliva has been proposed as a possible substitute to support testing at the population level. Here we describe the set-up of a laboratory, in an ac… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 20 publications
0
2
0
Order By: Relevance
“…Saliva with high viscosity is challenging for both laboratory-based testing and POC diagnostic applications involving lateral flow assay and paper-based analytical devices. The observed reduction in saliva viscosity, due to the mechanical shearing effects of the SHEAR SCD filter, can ease the pipetting procedures in laboratory-based saliva testing reducing pipetting errors, risk of environmental cross contamination and processing time required (10,11,13). Furthermore, while the viscosity of supernatant after centrifugation was comparable to the viscosity of SHEAR SCD processed saliva, implementation of SHEAR SCD for POC application is more feasible since it does not require additional equipment.…”
Section: Shear Scd Improves the Physical Properties Of Saliva For Dia...mentioning
confidence: 97%
See 1 more Smart Citation
“…Saliva with high viscosity is challenging for both laboratory-based testing and POC diagnostic applications involving lateral flow assay and paper-based analytical devices. The observed reduction in saliva viscosity, due to the mechanical shearing effects of the SHEAR SCD filter, can ease the pipetting procedures in laboratory-based saliva testing reducing pipetting errors, risk of environmental cross contamination and processing time required (10,11,13). Furthermore, while the viscosity of supernatant after centrifugation was comparable to the viscosity of SHEAR SCD processed saliva, implementation of SHEAR SCD for POC application is more feasible since it does not require additional equipment.…”
Section: Shear Scd Improves the Physical Properties Of Saliva For Dia...mentioning
confidence: 97%
“…Viscous matrix is troublesome as it complicates accurate sample processing (e.g. pipetting of accurate volumes) and automation (10)(11)(12)(13)(14). Additionally, salivary mucin networks form complexes with some of the proteins (15), potentially reducing their availability for detection.…”
Section: Introductionmentioning
confidence: 99%