2020
DOI: 10.1364/oe.387027
|View full text |Cite
|
Sign up to set email alerts
|

Detection of phenol by incorporation of gold modified-enzyme based graphene oxide thin film with surface plasmon resonance technique

Abstract: In this study, the incorporation between gold modified-tyrosinase (Tyr) enzyme based graphene oxide (GO) thin film with surface plasmon resonance (SPR) technique has been developed for the detection of phenol. SPR signal for the thin film contacted with phenol solution was monitored using SPR technique. From the SPR curve, sensitivity, full width at half maximum (FWHM), detection accuracy (DA) and signal-to-noise ratio (SNR) have been analyzed. The sensor produces a linear response for phenol up to 100 µM with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 32 publications
(12 citation statements)
references
References 99 publications
0
12
0
Order By: Relevance
“…The limit of detection is calculated as 214 ppb. Hashim et al [50] prepared gold modified tyrosinase (Tyr) enzyme-based graphene oxide (GO) thin film on surface plasmon resonance (SPR) sensor surface for phenol detection. The thin film prepared was characterized by using atomic force microscopy (AFM).…”
Section: Discussionmentioning
confidence: 99%
“…The limit of detection is calculated as 214 ppb. Hashim et al [50] prepared gold modified tyrosinase (Tyr) enzyme-based graphene oxide (GO) thin film on surface plasmon resonance (SPR) sensor surface for phenol detection. The thin film prepared was characterized by using atomic force microscopy (AFM).…”
Section: Discussionmentioning
confidence: 99%
“…In addition to sensitivity and binding affinity parameters, full width at half maximum (FWHM) is also an important parameter, which the value should be as small as possible for a good sensor. A smaller value of FWHM implies a narrow and sharp reflectance curve, signifying a better detection accuracy of measurements [67][68][69]. The variation of FWHM with respect to Ni(II) ion concentrations is shown in Figure 6.…”
Section: Spr Parametersmentioning
confidence: 99%
“…Surface plasmon resonance (SPR) strategy has drawn great attention as an economical, label-free tool because of its ability to detect target compounds in high sensitivity, real-time manner and rapid detection [ 42 , 43 , 44 , 45 , 46 , 47 , 48 ]. The Kretschmann configuration-based SPR method works by detecting the resonance in the form of charge density oscillations between the analyte and a metal thin film [ 49 , 50 , 51 , 52 , 53 , 54 , 55 ].…”
Section: Optical Sensorsmentioning
confidence: 99%