2013
DOI: 10.1007/s00604-013-1022-7
|View full text |Cite
|
Sign up to set email alerts
|

Detection of lead(II) using an glassy carbon electrode modified with Nafion, carbon nanotubes and benzo-18-crown-6

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
32
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(33 citation statements)
references
References 27 publications
1
32
0
Order By: Relevance
“…However, the profile of CNT bundle became unapparent, indicating that Nbim and CNTs were miscible throughout the electrode surface. This result was similar to the former reports [34].…”
Section: Characterization Of Nbim/cnt Composite Filmsupporting
confidence: 94%
“…However, the profile of CNT bundle became unapparent, indicating that Nbim and CNTs were miscible throughout the electrode surface. This result was similar to the former reports [34].…”
Section: Characterization Of Nbim/cnt Composite Filmsupporting
confidence: 94%
“…Nevertheless, regarding the sensitivities considered as the value obtained from the slope of the calibration curves, it can be mentioned that: i) using CB-18-crown-6-GEC, Pb(II) was the metal ion showing better sensitivity; and ii) using CB-15-crown-5-GEC, Cu(II) was the most sensitive metal. The LOD of the assay for the three metal ions in both modified electrodes varied from 1.5 to 4.7 μg L −1 depending on the metal ion ( than the values reported in earlier studies [6,7,13]. In the case of Cd(II) no previous LOD and LOQ data is available in the literature.…”
Section: Repetitivity and Reproducibilitymentioning
confidence: 59%
“…Particularly, crown ethers are well-known to form complexes with alkaline ions, alkaline earth metals, lanthanides and transition metal ions. Surprisingly, studies devoted to complexation with transition metal ions are scarce and only few works using crown ether-modified electrodes are published for the determination of lead [5][6][7], mercury [8,9], silver [10], thallium [11], palladium [12] and copper [13].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, Nafion is a cation exchanger with a high cation exchange capacity. Therefore, the Nafion film-modified GCE shows a higher accumulation efficiency for Pb 2+ and finally enhances the stripping current [1,40,41]. Measurements were taken using an optimized system based on that developed by Dai et al [42], with 0.1 M HCl as the supporting electrolyte.…”
Section: Resultsmentioning
confidence: 99%