2013
DOI: 10.4236/jbnb.2013.42020
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Influenza Viruses Attached to an Optical Disk

Abstract:

Detection of polystyrene beads with a diameter of 100 nm was conducted using an optical disk drive tester equipped with a laser of 405 nm wavelength and an objective lens with a numerical aperture of 0.65. The polystyrene beads were used to mimic the influenza virus. A grooved disk with a (ZnS)85(S… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
7
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…10) However, the mark edges can be clearly recognized, and this is acceptable for the present study. 8) On the right-hand side of Fig. 3, some intensity dips were observed for the all scanned data for (a) to (h).…”
mentioning
confidence: 88%
See 2 more Smart Citations
“…10) However, the mark edges can be clearly recognized, and this is acceptable for the present study. 8) On the right-hand side of Fig. 3, some intensity dips were observed for the all scanned data for (a) to (h).…”
mentioning
confidence: 88%
“…There are a number of research papers on bacteria detection by optical methods [3][4][5] and on the use of optical disk technology for the detection of various biological substances. [6][7][8] Arai et al prepared a biotinylated disk sample surface to bind streptavidin and detected the reflected light intensity change caused by the attachment of the streptavidin to the surface. 6) Tsujita et al recently used NeutrAvidinÔimmobilized magnetic beads to enhance its binding with biotin ligands formed on a disk sample surface by applying a magnetic field.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…[8][9][10] We also successfully obtained a scanned image of E. coli dispersed on an optical disk, using a commercially available optical disk system, by detecting reflected light from the optical disk. [11][12][13][14] However, we found that it was difficult to distinguish E. coli from other contaminants in the imaging results. Therefore, in this study, we developed a new optical disk system that can detect the intensity of the light transmitted through the optical disk and distinguish E. coli from other contaminants by staining treatment.…”
mentioning
confidence: 80%
“…In that case, aptamer helps to detect the pathogenic biomarkers at the earlier stage. Different aptamers were generated against Influenza viral types A and B [3,[7][8][9]. Lakshmipriya et al [3] have selected aptamers against influenza B virus and detected influenza with the waveguide-mode sensor and reached the limit of detection to 100 picomolar (pM), which is a much lower level than influenza antibody-mediated detection.…”
Section: Diagnosis Of Pathogens By Aptamermentioning
confidence: 99%