Proceedings of the 24th Intersociety Energy Conversion Engineering Conference
DOI: 10.1109/iecec.1989.74455
|View full text |Cite
|
Sign up to set email alerts
|

Detection of incipient and low current faults in electric distribution systems (of spacecraft)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0
5

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 9 publications
0
1
0
5
Order By: Relevance
“…Computer software based fault detection algorithms which attempt to identify faults via a "footprint" or "signature" of different failure modes offer possibilities of improved circuit protection. Faults can be detected for example, by identifying their unique energy characteristics or the "arcing signatures" [27]. These Autonomous Power System methods, and others, apply knowledge based "expert" systems which have the ability to "learn" and adapt to the unique characteristics of the system over time.…”
Section: Fig 10 Zone Fault Detector Using Optical-fiber Coil [26]mentioning
confidence: 99%
“…Computer software based fault detection algorithms which attempt to identify faults via a "footprint" or "signature" of different failure modes offer possibilities of improved circuit protection. Faults can be detected for example, by identifying their unique energy characteristics or the "arcing signatures" [27]. These Autonomous Power System methods, and others, apply knowledge based "expert" systems which have the ability to "learn" and adapt to the unique characteristics of the system over time.…”
Section: Fig 10 Zone Fault Detector Using Optical-fiber Coil [26]mentioning
confidence: 99%
“…Os principais motivos desta dificuldade são os reduzidos valores de amplitude de corrente e seu comportamento errático. É reportado que os relés para detecção de FAI detectam apenas 50 a 60% destes eventos [10], [11] e que estas faltas podem permanecer por dias [12]. Em 200 testes, realizados em tensão de 13,8 kV, sob diversas condições de operação, menos de 10% das faltas foram extintas por relés de sobrecorrente de fase e terra [12].…”
Section: Análise Do Espectro De Baixaunclassified
“…É reportado que os relés para detecção de FAI detectam apenas 50 a 60% destes eventos [10], [11] e que estas faltas podem permanecer por dias [12]. Em 200 testes, realizados em tensão de 13,8 kV, sob diversas condições de operação, menos de 10% das faltas foram extintas por relés de sobrecorrente de fase e terra [12]. Em razão dos motivos apresentados fica claro que é de grande relevância estudar este fenômeno, a fim de proteger pessoas e patrimônios e que ainda existe espaço e necessidade de pesquisas na área.…”
Section: Análise Do Espectro De Baixaunclassified
See 2 more Smart Citations