Detection of Human Cholangiocarcinoma Markers in Serum Using Infrared Spectroscopy

Abstract: Cholangiocarcinoma (CCA) is a malignancy of the bile duct epithelium. Opisthorchis viverrini infection is a known high-risk factor for CCA and in found, predominantly, in Northeast Thailand. The silent disease development and ineffective diagnosis have led to late-stage detection and reduction in the survival rate. Attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) is currently being explored as a diagnostic tool in medicine. In this study, we apply ATR-FTIR to discriminate CCA ser… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 55 publications
0
7
0
Order By: Relevance
“…The different performances of a classification model in terms of % accuracy, sensitivity, and specificity are not only influenced by the algorithm used, but also the input attributes, data complexity, and sample size. Until now, there has been no agreement on the best method of analysis [42]. A limitation of this study was the number of spectra used for building the classification models.…”
Section: Discussionmentioning
confidence: 90%
See 3 more Smart Citations
“…The different performances of a classification model in terms of % accuracy, sensitivity, and specificity are not only influenced by the algorithm used, but also the input attributes, data complexity, and sample size. Until now, there has been no agreement on the best method of analysis [42]. A limitation of this study was the number of spectra used for building the classification models.…”
Section: Discussionmentioning
confidence: 90%
“…Classification model performance was evaluated in terms of % accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) [42,50]. A confusion matrix or 2 × 2 table (Table 1) was employed for calculations with the following formulas:…”
Section: Classification Model Evaluationmentioning
confidence: 99%
See 2 more Smart Citations
“…ATR-FTIR is characterized by high sensitivity in biomedical diagnostics[ 52 ] and can detect spectral markers of many pathologies in physiological liquids such as saliva or blood serum. ATR-FTIR was used to detect lung[ 53 ], bile duct[ 54 ], ovary[ 55 , 56 ], breast[ 57 ], and brain[ 58 , 59 ] tumors in the blood serum samples. In a study by Butler et al [ 59 ], the team described the methodology of using ATR-FTIR in an early screening of brain tumor patients with sensitivity and specificity of 93.2% and 92.8%, respectively.…”
Section: Molecular Spectroscopymentioning
confidence: 99%