Abstract: The application of single photon ionization in combination with mass-selective detection by time-of-flight mass spectrometry is described for the rapid detection of the nitro-containing explosives and explosives-related compounds nitrobenzene, 1,3-dinitrobenzene, o-nitrotoluene, 2,4-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the peroxide-based explosive triacetone triperoxide in the gas phase. The technique is demonstrated to be a plausible approach for laser-based rapid detection of explosives. The… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
87
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 127 publications
(88 citation statements)
references
References 60 publications
(99 reference statements)
1
87
0
Order By: Relevance
“…Interestingly, the deprotonated TNT signal (m/z 226) was exclusively observed in SESI (Figure 2f), suggesting that the mechanism of SESI is quite different from DESI or EESI. TNT radical anions were also exclusively observed in single photon ionization mass spectrometry (Figure 2g) [97,98]. The relative abundance of the various signals in the mass spectra thus depend on how and how much energy is deposited into the ions.…”
Section: Case Study Ii: Direct Detection Of Explosives On "Real Worldmentioning
confidence: 94%
“…Interestingly, the deprotonated TNT signal (m/z 226) was exclusively observed in SESI (Figure 2f), suggesting that the mechanism of SESI is quite different from DESI or EESI. TNT radical anions were also exclusively observed in single photon ionization mass spectrometry (Figure 2g) [97,98]. The relative abundance of the various signals in the mass spectra thus depend on how and how much energy is deposited into the ions.…”
Section: Case Study Ii: Direct Detection Of Explosives On "Real Worldmentioning
confidence: 94%
“…The LOD of the instrument towards 2,4-DNT was ultimately calculated to be 30 pptv (2.4 pg). In previous studies, the LOD of gas chromatography/ PI-MS towards 2,4-DNT was $ 40 ppbv (2s), [6] and the LOD of sole PI-MS towards 2,4-DNT was 40 ppbv (3s) [22]. The LOD obtained using this technique was improved by 3 orders of magnitude as compared to the previous reports.…”
Section: Resultsmentioning
confidence: 68%
“…The mass peak at m/z 165 was the base peak in the spectrum with an intensity of 24790 counts and was thus used as the h value. Note that this spectrum was obtained for using a saturated vapor of 2,4-DNT and the concentration of 2,4-DNT (c) was 170 ppbv (298 K) [6]. The LOD of the instrument towards 2,4-DNT was ultimately calculated to be 30 pptv (2.4 pg).…”
Section: Resultsmentioning
confidence: 96%