2022
DOI: 10.1016/j.dyepig.2022.110714
|View full text |Cite
|
Sign up to set email alerts
|

Detection of environmentally hazardous hypochlorite in pure water with a novel fluorescent chemosensor: Application to water samples, commercial disinfectants, test strips, and zebrafish

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 51 publications
0
3
0
Order By: Relevance
“…4,5 Excessive ROS including HClO/ ClO − , H 2 O 2 , OONO − , and O 2 − are often considered to be the key factors of malignant tumors, atherosclerosis, and neurodegenerative diseases in the human immune system. [6][7][8] In addition, HClO/ClO − is also commonly used as the main component of bleach and disinfectant in drinking water, [9][10][11][12] in which the high concentration of HClO/ClO − will pose a threat to the water recycling environment and human wellbeing. Given the above consideration, a detection method of HClO/ClO − with high sensitivity and selectivity in practical cases is urgently needed, especially those applicable probes that work effectively in water systems.…”
Section: Introductionmentioning
confidence: 99%
“…4,5 Excessive ROS including HClO/ ClO − , H 2 O 2 , OONO − , and O 2 − are often considered to be the key factors of malignant tumors, atherosclerosis, and neurodegenerative diseases in the human immune system. [6][7][8] In addition, HClO/ClO − is also commonly used as the main component of bleach and disinfectant in drinking water, [9][10][11][12] in which the high concentration of HClO/ClO − will pose a threat to the water recycling environment and human wellbeing. Given the above consideration, a detection method of HClO/ClO − with high sensitivity and selectivity in practical cases is urgently needed, especially those applicable probes that work effectively in water systems.…”
Section: Introductionmentioning
confidence: 99%
“…[40][41][42] 2-Hydrazinyl-N,N,N-trimethyl-2-oxoethan-1-aminium chloride (Girard's reagent T) has recently been used as one of the moieties for increasing water solubility of chemosensors. [43][44][45] Therefore, we expected that the combination of the NBD and Girard's reagent T would produce a water-soluble colorimetric chemosensor with a hydrolytic response to ClO À .…”
Section: Introductionmentioning
confidence: 99%
“…In addition, NBD‐based chemosensors that detect various analytes through hydrolysis and thiolysis mechanisms are being developed 40–42 . 2‐Hydrazinyl‐ N , N , N ‐trimethyl‐2‐oxoethan‐1‐aminium chloride (Girard's reagent T) has recently been used as one of the moieties for increasing water solubility of chemosensors 43–45 . Therefore, we expected that the combination of the NBD and Girard's reagent T would produce a water‐soluble colorimetric chemosensor with a hydrolytic response to ClO − .…”
Section: Introductionmentioning
confidence: 99%