2017
DOI: 10.1109/tdei.2016.005933
|View full text |Cite
|
Sign up to set email alerts
|

Detection of conductive layers short circuit in HV condenser bushings using Frequency Domain Spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 9 publications
0
6
0
Order By: Relevance
“…Moreover, it is essential to note that all the simulation is done at a reference temperature, which is 20 °C. The obtained results in this section are along with [13][14][15][16][17][18]. As mentioned earlier, there are other researches in which the impact of the OIP moisture content on FDS curves is investigated, or the moisture content of the OIP is estimated using a mathematical equation.…”
Section: Fem Model Of Oip Bushingmentioning
confidence: 89%
See 1 more Smart Citation
“…Moreover, it is essential to note that all the simulation is done at a reference temperature, which is 20 °C. The obtained results in this section are along with [13][14][15][16][17][18]. As mentioned earlier, there are other researches in which the impact of the OIP moisture content on FDS curves is investigated, or the moisture content of the OIP is estimated using a mathematical equation.…”
Section: Fem Model Of Oip Bushingmentioning
confidence: 89%
“…The results indicate that the moisture content in OIP bushings can be estimated by their proposed method. Several kinds of literature like [15][16][17][18][19][20][21] dispute the FDS method's preference over the typical tests. However, none of those works establish a comprehensive instruction for FDS result interpretation.…”
Section: Introductionmentioning
confidence: 99%
“…The key connection component between the power transformer and the grid is bushing. Among them, the capacitive oil-paper bushing plays a vital role in the safe and stable operation of power systems [1][2][3]. Moisture is one of the most important factors affecting the insulation state of bushing [4,5].…”
Section: Introductionmentioning
confidence: 99%
“…IEC 60137 standard specifies the calculation method for the hot spot temperature of conventional HVAC bushings. However, the current-carrying connection structure and operating conditions of the RIP valve side bushing are different from those of HVAC bushings, and there is a big difference between the calculation result of the hot spot temperature value and the actual value [19][20][21]. Despite having passed the temperature rise test, internal breakdown failures of RIP valve side bushings, caused by overheating under long-term load current [22][23][24], might still happen.…”
Section: Introductionmentioning
confidence: 99%