2018
DOI: 10.1016/j.bios.2018.04.022
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Bisphenol A in aqueous medium by screen printed carbon electrodes incorporating electrochemical molecularly imprinted polymers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
24
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 81 publications
(33 citation statements)
references
References 34 publications
0
24
0
Order By: Relevance
“…The correct leaching of BaP or BPA from e-MIPs was confirmed by the absence of any major characteristic band of these targets in the e-MIP spectrum and by the high similitude of e-MIPs and e-NIPs spectra. SEM pictures revealed spherical particles with average diameters from 0.22 µm for e-MIP-VFc-DVB [4] to 4.40 µm for the e-MIP-FcMMA-EDMA [5]. Adsorptions of targets were studied in aqueous medium by batch experiments after an equilibration time of 24 h. The binding studies revealed that the higher values are obtained with introduction of 4-VP and DVB.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The correct leaching of BaP or BPA from e-MIPs was confirmed by the absence of any major characteristic band of these targets in the e-MIP spectrum and by the high similitude of e-MIPs and e-NIPs spectra. SEM pictures revealed spherical particles with average diameters from 0.22 µm for e-MIP-VFc-DVB [4] to 4.40 µm for the e-MIP-FcMMA-EDMA [5]. Adsorptions of targets were studied in aqueous medium by batch experiments after an equilibration time of 24 h. The binding studies revealed that the higher values are obtained with introduction of 4-VP and DVB.…”
Section: Resultsmentioning
confidence: 99%
“…A decrease of current intensity with addition of BaP in the electrolytic solution is also observed with a more important impact for copolymers based on VFc-EDMA with limits of detection of 0.93 and 2.47 µM for e-MIP VFc-EDMA-CPE and e-MIP VFc-4VP-EDMA-CPE, respectively. This strategy was extended to the detection of bisphenol A (BPA) [5]. For this FcMMA was taken as functional redox tracer with 4-VP co-monomer, EDMA as crosslinker.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, we extended this strategy to e-MIP for bisphenol A (BPA) and integrated these new e-MIPs in screen printed electrodes. A limit of detection of 0.06 nmol/L of BPA was obtained [10,11]. This strategy has also been taken up to detect vancomycin, an antibiotic target, with electroactive MIPs prepared by solid-phase synthesis with different amounts of VFc and ferrocenylmethyl methacrylate into polymerization mixture [12].…”
Section: Introductionmentioning
confidence: 99%
“…By using MIT, low cost and high stability materials (known as molecularly imprinted polymers, MIPs), containing cavities able to recognize selectively templates ranging from valuable or toxic small molecules can be easily prepared. Consequently, these attributes make MIPs ideal for replacing the extensive materials commonly used in solid-phase extraction [4,5], drug delivery [6], sensors [7,8] and purification and separation [9][10][11].…”
mentioning
confidence: 99%