1991
DOI: 10.1086/186091
|View full text |Cite
|
Sign up to set email alerts
|

Detection of a feature at 0.44 MeV in the Crab pulsar spectrum with FIGARO II - A redshifted positron annihilation line?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
14
1

Year Published

1992
1992
2009
2009

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 0 publications
2
14
1
Order By: Relevance
“…In no case did we Ðnd a statistically signiÐcant signal. It is not impossible that this is a line whose intensity varies in time so that the 3 p value of Massaro et al (1991) and our lower limitÈsmaller by a factor of nearly 4Èare both correct. Some hints of a long time variation in the relative strengths of c-ray intensities from the main pulse and the interpulse of the Crab pulsar were suggested by a comparison between COS B data and CGRO EGRET data (Nolan et al 1993).…”
Section: Discussionmentioning
confidence: 62%
See 3 more Smart Citations
“…In no case did we Ðnd a statistically signiÐcant signal. It is not impossible that this is a line whose intensity varies in time so that the 3 p value of Massaro et al (1991) and our lower limitÈsmaller by a factor of nearly 4Èare both correct. Some hints of a long time variation in the relative strengths of c-ray intensities from the main pulse and the interpulse of the Crab pulsar were suggested by a comparison between COS B data and CGRO EGRET data (Nolan et al 1993).…”
Section: Discussionmentioning
confidence: 62%
“…We not only looked at emission in the three "" classic ÏÏ regions of the pulsar phase (peak 1, peak 2, and the bridge region) but also in the phase bins used by Massaro et al (1991). We also used the total Ñux from the pulsar and tried to Ðnd an enhancement by choosing those phase bins in the light curve for the central energy range (near 440 keV) that showed a positive deviation above the average light-curve shape.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Neither "Pulsed" nor "Unpulsed" mean spectra do not demonstrate emission line features. The 3σ upper limits on flux from the possible 440 keV red shifted positron annihilation line (see also [6], [7], [8]) are 3 × 10 −4 and 6 × 10 −4 ph/s/cm 2 , in "Pulsed" and "Unpulsed" emission respectively. These upper limits are higher than the line intensity that was observed previously with other instruments ( [6], [7]).…”
Section: Discussionmentioning
confidence: 98%