2018
DOI: 10.1007/978-1-4939-8576-0_14
|View full text |Cite
|
Sign up to set email alerts
|

Detection and Quantitative Analysis of Dynamic GPCRs Interactions Using Flow Cytometry-Based FRET

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 65 publications
0
4
0
Order By: Relevance
“…Prior to analysis, cells were passed through a 100 μm nylon mesh cell strainer (#10199-658; VWR) and collected in 5 mL round-bottom polystyrene tubes (#352054; Corning). The fcFRET analysis was performed on a FACS AriaII cytometer (BD Biosciences) according to the protocol optimized in our group . Briefly, EGFP was excited at 488 nm from a blue laser and detected with a 525/50 nm bandpass filter, whereas tRFP was excited at 561 nm from a yellow/green laser and detected with a 610/20 nm bandpass filter.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Prior to analysis, cells were passed through a 100 μm nylon mesh cell strainer (#10199-658; VWR) and collected in 5 mL round-bottom polystyrene tubes (#352054; Corning). The fcFRET analysis was performed on a FACS AriaII cytometer (BD Biosciences) according to the protocol optimized in our group . Briefly, EGFP was excited at 488 nm from a blue laser and detected with a 525/50 nm bandpass filter, whereas tRFP was excited at 561 nm from a yellow/green laser and detected with a 610/20 nm bandpass filter.…”
Section: Methodsmentioning
confidence: 99%
“…The fcFRET analysis was performed on a FACS AriaII cytometer (BD Biosciences) according to the protocol optimized in our group. 65 Briefly, EGFP was excited at 488 nm from a blue laser and detected with a 525/50 nm bandpass filter, whereas tRFP was excited at 561 nm from a yellow/green laser and detected with a 610/20 nm bandpass filter. The FRET signal between EGFP and tRFP was measured by excitation at 488 nm from blue laser and detection with a 610/20 nm bandpass filter located on the same laser.…”
Section: ■ Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, co-location of the two receptor protomers was observed in primary hippocampal and hypothalamic cultures of postnatal day 1 (P1) Sprague Dawley rats. Wallace Fitzsimons et al ( 2019 ) showed increased trafficking of the OXTR/GHS-R1a pair following co-expression (Chruścicka et al, 2018 ). Notably, the most significant finding was that the formation of the GHS-R1a-OXTR heterocomplex led to an attenuation of oxytocin-induced calcium mobilization mediated via G alpha q signaling.…”
Section: Oxytocin Heteroreceptor Complexesmentioning
confidence: 99%