Detection and quantitation of host cell proteins in monoclonal antibody drug products using automated sample preparation and data-independent acquisition LC-MS/MS

Abstract: Ensuring the removal of host cell proteins (HCPs) during downstream processing of recombinant proteins such as monoclonal antibodies (mAbs) remains a challenge. Since residual HCPs might affect product stability or safety, constant monitoring is required to demonstrate their removal to be below the regulatory accepted level of 100 ng/mg. The current standard analytical approach for this procedure is based on ELISA; however, this approach only measures the overall HCP content. Therefore, the use of orthogonal m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
6
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 25 publications
(34 reference statements)
2
6
0
1
Order By: Relevance
“…We [38, 39] and others [33, 66] have previously demonstrated the benefits of using DIA methods and MS2‐based quantification to accurately monitor HCP impurities, and it is clearly confirmed in the current study. While DDA allowed the identification of the highest number of protein groups, namely 135, against 115 in DIA (Figure 1D), DIA allowed quantifying 100 HCPs (222 peptides) against 68 in DDA (121 peptides).…”
Section: Resultssupporting
confidence: 83%
See 1 more Smart Citation
“…We [38, 39] and others [33, 66] have previously demonstrated the benefits of using DIA methods and MS2‐based quantification to accurately monitor HCP impurities, and it is clearly confirmed in the current study. While DDA allowed the identification of the highest number of protein groups, namely 135, against 115 in DIA (Figure 1D), DIA allowed quantifying 100 HCPs (222 peptides) against 68 in DDA (121 peptides).…”
Section: Resultssupporting
confidence: 83%
“…We [38,39] and others [33,66] have previously demonstrated the benefits of using DIA methods and MS2-based quantification to accurately monitor HCP impurities, and it is clearly confirmed in the current study.…”
Section: Digging Deeper Into the Hcp Landscape With Data Independent ...supporting
confidence: 84%
“…S6 and S7 . These critical biotransformation should be carefully monitored during quality control, biosimilar development or treatment cycle to guarantee efficacy and safety 44 , 45 , 46 , 47 , 48 .
Figure 7 Analytical process for non-Hodgkin's lymphoma patient serum and example data of identified and confirmed peptides using ZenoTOF TM 7600 system.
…”
Section: Resultsmentioning
confidence: 99%
“…Dado que espectrômetros de massa tem a capacidade de detectar quantidades muito reduzidas de analitos de interesse, especialmente quando operando em alta resolução, torna-se viável a identificação dos peptídeos derivados dessas proteínas residuais. Proteínas de células CHO foram identificadas em instrumento com analisador híbrido quadrupolo-orbitrap mostrando proteínas presentes em determinadas condições de cultivo utilizando aquisição independente de dados (STRASSER et al, 2021) e também em aquisição dependente de dados (KREIMER et al, 2017).…”
Section: Análise De Proteínas Da Célula Hospedeiraunclassified