2018
DOI: 10.1016/j.snb.2017.08.056
|View full text |Cite
|
Sign up to set email alerts
|

Detection and quantification of lung cancer biomarkers by a micro-analytical device using a single metal oxide-based gas sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
63
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 69 publications
(63 citation statements)
references
References 44 publications
0
63
0
Order By: Relevance
“…The comparison is shown in Table 2 . Furthermore, due to the miniaturization of the sensor size and the simplicity of resistance measurement, this kind of sensor would be easily integrated into a sensor array and a micro-preconcentrator to achieve better discrimination and sensitivity [ 3 , 21 , 22 ].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The comparison is shown in Table 2 . Furthermore, due to the miniaturization of the sensor size and the simplicity of resistance measurement, this kind of sensor would be easily integrated into a sensor array and a micro-preconcentrator to achieve better discrimination and sensitivity [ 3 , 21 , 22 ].…”
Section: Resultsmentioning
confidence: 99%
“…The detection of VOCs in the environment or in exhaled breath has received considerable attention and is becoming increasingly important in the development of point of care testing (POCT) devices and Internet of Things (IoT) nodes [ 1 , 2 , 3 , 4 , 5 , 6 , 7 ]. The development of versatile materials enables advances in gas sensors or electric nose detection.…”
Section: Introductionmentioning
confidence: 99%
“…These miniaturized GC were conceived for a wide variety of applications requiring very sensitive instruments such as environmental monitoring [20], [35], early cancer diagnosis [23], [36] or food quality control [37]. Therefore, all GC systems include a preconcentrator that improves the detector sensitivity to tens or hundreds of ppb in the case of sensors and, to ppb or even hundreds of ppt in the case of PID detectors.…”
Section: Comparison With the Existing Instrumentsmentioning
confidence: 99%
“…The abnormal level of EBM carries some information about the disease status and treatment efficiency (Das & Pal, 2020). Many clinical trials focused on EBM for the diagnosis of disease ranging from respiratory, diabetes to cancer (Brinkman et al, 2020; Chang et al, 2018; Gregis et al, 2018; Kabir et al, 2019; Rahman et al, 2020).…”
Section: Introductionmentioning
confidence: 99%